3. Specification

3.1 Measuring Range & Accuracy (Accuracy guaranteed at 23ºC ± 5ºC, humidity <75%) 

3.2 General Specification

•  The maximum voltage allowed between terminal and ground: 600 VDC or 600 VAC

•  Certifications and Compliance: Conforms to UL std. 61010-1, UL std. 61010-031, UL std. 61010-2-030, UL std. 

61010-2-033, Certified to CSA std. C22.2 No. 61010-1, CSA std. 61010-031, CSA std. 61010-2-030, CSA std. 

61010-2-033, CE, CAT III 600V 

•  Altitude: Maximum 2000m

•  Display: 3-3/4-digit LCD, 3999 count 

•  Sampling time: 2 - 3 times / sec

•  IP Degree: IP20

•  Bluetooth Range: 10 Meters

•  Automatic power off: 15 Minutes (Unless disabled)

•  Battery type: (2) 1.5V LR44

•  Operating temperature: 0˚C ~ 40˚C

•  Storage temperature: -10˚C ~ 50˚C

•  Size: 4.38" x 2.10" x 0.5" (111mm x 53mm x 12.7mm)

•  Weight: 2.47 oz. (70 grams) (Including batteries)

3.3 Accessories

•  2 LR44 batteries

•  CAT III 600V probe tip caps

4. Preparation for Measurement

4.1 Check the Condition of the Meter

Do no use a meter with visible signs of damage. Examine the meter housing before you use the product. Look for 

cracks, missing plastic or exposed metal. Carefully examine the wire insulation. Pay close attention to where the 

wire enters the meter and attaches to the probes.

4.2 Check the Battery Voltage

Press the select button to power the unit on. Confirm that the low battery symbol          is not displayed on the LCD 

screen. If the low battery symbol          is displayed follow the instructions in Section 8, Battery Replacement.

SETTING

RANGE

RESOLUTION

ACCURACY

DC Voltage

400mV

100mV

±1.2%+3

4V

0.001V

±.8%+3

40V

0.01V

400V

0.1V

600V

1V

±1.2%+3

AC Voltage

4V

0.001V

±1.0%+5

40V

0.01V

400V

0.1V

600V

1V

±1.5%+5

Resistance

400

Ω

0.1

Ω

±1.5%+10

4k

Ω

0.001k

Ω

±.1.2%+6

40k

Ω

0.01k

Ω

±.1.0%+4

400k

Ω

0.1k

Ω

4M

Ω

0.001M

Ω

±.2.0%+4

40M

Ω

0.01M

Ω

TEMPERATURE COEFFICIENT

<.1 X (SPECIFIED ACCURACY)/°C

4

Summary of Contents for SDMM10000

Page 1: ...st Leads CAT III 600V Probe Tip Caps Figure 1 Figure 2 Display Power SELECT Button AUTO Auto Ranging mV V Millivolt Volt k M Ohm Kiloohm Megaohm Resistance Negative Value Diode Check Direct Current Lo...

Page 2: ...ll the safety instructions contained in the manual It is essential that all safety instructions are adhered to Failure to follow the safety instructions may cause injury instrument damage The symbol i...

Page 3: ...Voltage Categories To ensure safe operation of measuring instruments IEC61010 establishes safety standards for various electrical environments specified as CAT I through CAT IV and called measurement...

Page 4: ...ies 3 3 Accessories 2 LR44 batteries CAT III 600V probe tip caps 4 Preparation for Measurement 4 1 Check the Condition of the Meter Do no use a meter with visible signs of damage Examine the meter hou...

Page 5: ...3 Confirm OL is displayed on the screen 4 Short the tips of the test leads together and confirm the screen shows near zero 5 Connect the test leads across the device to be tested 6 The resistance of...

Page 6: ...perry SMARTmeter app 2 Touch the icon to open 7 4 Connecting Your Smart Device 1 Make sure that your smart device has Bluetooth enabled 2 Turn on the SMARTmeter by pressing and releasing the SELECT bu...

Page 7: ...eping sound if the value displayed exceeds the range entered 6 To deactivate the alert press the Alert button select Off and press OK 7 7 Data File Management 7 7 1 Rename Save 1 Once data has been co...

Page 8: ...ish to change the name enter the new name and press Save iOS only 5 If you wish to continue sharing with the default or previously assigned name just press Save iOS only 6 You will be given the option...

Page 9: ...plications The distributor is authorized to extend the foregoing limited warranty to its original purchasers in connection with the sales of Sperry products provided that such products shall not have...

Reviews: