B.
STAGE GAIN CHARTS
2.
RX Stage Gain
- Volume Maximum Clockwise
- Connect a signal generator to the test point through a 0.01 uF capacitor (except at RX
ANT and AUD connect direct)
- Frequency of signal generator adjusted to result in 1000 Hz audio output
- Input levels should be adjusted for 2.4 V RMS across the speaker or 30 Ohm load 250
mW.
TEST POINT
INPUT LEVEL RMS
INPUT FREQUENCY
ANT binding post
RX H.F.O. TP101
1st IF TP102
2nd IF TP103
Audio TP109
1 uV
1 uV
20 uV
18 mV
3 - 6 mV
Channel Frequency
455.5 kHz
455.5 kHz
455.5 kHz
1000 Hz
3. Oscillators
Oscillator levels are given on the schematic.
C.
REPLACEMENT OF PA
The PA module LPA2 - SCL #67-076 may be replaced by following the replacement
instructions on the next page.