3. Module
Adjustment
a) PA Bias R153. Measure supply current while pushing the PTT switch but without
modulation. Turn R153 fully counter clockwise. Advance R153 for increase of about
5 mA (4 mA to 7 mA).
b) Operate transmitter into dummy lead following section VI D5 of the manual. If
antenna current falls within 220 to 360 mA RF, retune as described in manual.
c) If required antenna current cannot be achieved, follow Section VI E3 except instead of
step a) in that section, substitute step a) immediately above. Then tune the transmitter