VI.
TROUBLESHOOTING
TROUBLESHOOTING YOUR ZX-1
MAIN CIRCUIT BREAKER
A 50-amp main circuit breaker reset button is
located on the power base. Check the 50-amp
breaker and reset if ZX-1 stops operating.
If the main circuit breaker has tripped, some
causes might be:
•
Driving up a long, steep hill
•
Driving over a curb
•
Run-down batteries
•
Wet batteries or Electronics
•
ZX-1 or components become too hot
•
Low tire pressure
When operating the ZX-1, battery voltages are
reduced and battery current must increase to
satisfy the motors demand. This effect can
cause a heavy current draw that may also trip
the main circuit breaker.
RESETTING MAIN CIRCUIT BREAKER
If the main circuit breaker trips as a result of
low batteries or because of a temporary
overload, it is acceptable to reset the circuit
breaker as follows:
1.
Wait at least ten minutes for the control
system electronics to return to normal
operating temperature.
2.
Power-off ZX-1.
3.
Press main circuit breaker to reset.
4.
Power-on ZX-1
CAUTION
•
If the main circuit breaker continues to
trip, there is probably an underlying elec-
trical fault that needs attention. Do not
continue to reset the main circuit breaker
without correcting the underlying electrical
issue.
If the lithium batteries are low in voltage and
the operator is traveling up a grade, the system
will automatically go into “Crawl mode” until a
level ground is attained.
BATTERY LED CODES
If a system trip occurs, operator may count
number of bars on battery LED indicator that
flash. Refer to the battery bar code
troubleshooting chart for a list of self
diagnostic actions (Table 3).
If malfunction still remains after performing
possible solution, contact authorized Spinergy
representative for repair.
NOTE
•
Left and right component positions are
identified with operator seated in wheel-
chair connected to ZX-1.