INTRODUCTION 

 

 

 

 

 

 

 

 

 

 

 

 
This appliance must be installed in accordance with the local, national and European 
regulations in force. Particular attention shall be given to the requirements regarding 
ventilation. Read the instructions before installing or using the appliance 
 
The appliance is designed for either high or low level installations. Failure to install the 
appliance correctly could invalidate any warranty or liability claims and lead to prosecution. 
Please refer to the methods of installation within this handbook. 
 
Our policy is one of continuous development and improvement. Specifications and 
illustrations may change subsequent to publication. 
 
Provision Of Ventilation 
The use of a gas cooking appliance results in the production of heat and moisture in a 
room in which it is installed. Ensure that the kitchen is well ventilated, keep natural 
ventilation holes open or install a mechanical ventilation device (mechanical extractor 
hood). 
Prolonged intensive use of the appliance may call for additional ventilation, for example 
opening a window, or more effective ventilation, for example increasing the level of 
mechanical ventilation where present. The room containing the appliance should have an 
air supply in accordance with local, national and European standards. 
 
IMPORTANT 
This appliance is suitable for use with LPG and should not be used on any other gas. The 
following gas pressures should be used. 
 
Gas Category 
 

CAT I

3

+ (28-30/37) 

 

 

CAT I

3

 B/P (30) 

BUTANE (G30) 28-30 mbar   

BUTANE (G30) 30 mbar 

PROPANE (G31) 37 mbar 

 

PROPANE (G31) 30 mbar 

 
Position 
This appliance must be positioned free from draughts, which may affect the combustion 
and in a manner that will prevent the accumulation of unburnt gas. When in use ensure 
that air vents are not inadvertently blocked or shut off. 
The location should ensure convenience of operation and service. Any adjoining wall 
surface situated within 200mm from the edge of any hob burner must be a suitable non-
combustible material. Any combustible construction above the hotplate must be at least 
500mm above the top of the burner and no construction shall be within 450mm above the 
top of the burner. 
 

IMPORTANT 
 

   THIS APPLIANCE IS SUITABLE FOR USE WITH LIQUEFIED PETROLEUM  

GAS (LPG) AND SHOULD NOT BE USED ON ANY OTHER GAS.  
 

   USE ONLY THE GAS PRESSURES SPECIFIED ABOVE  

 

 

Summary of Contents for 756

Page 1: ...this appliance in a well ventilated area Read the instructions before use SPINFLO LIMITED 19 Oakham Drive Parkwood Industrial Estate Rutland Road Sheffield S3 9QY ENGLAND TEL 44 0 114 273 8157 FAX 44 0 114 275 3094 FOR USE IN GB IE FR NL BE LU ES IT NO DE DK SE BUILD IN COOKING HOB MODELS H200F H250F H400F 756 854F FOR USE WITH LIQUIFIED PETROLEUM GAS ...

Page 2: ...2 MODEL RANGE ...

Page 3: ...3 INSTALLATION DETAILS ...

Page 4: ...w or more effective ventilation for example increasing the level of mechanical ventilation where present The room containing the appliance should have an air supply in accordance with local national and European standards IMPORTANT This appliance is suitable for use with LPG and should not be used on any other gas The following gas pressures should be used Gas Category CAT I3 28 30 37 CAT I3 B P 3...

Page 5: ...top of the Panrest In the case of appliances that do not have grills fitted the underside of the appliance must be shielded It is recommended that the shield be fabricated from non combustible material but if the enclosure is manufactured from combustible material then a minimum air space of 100mm must exist between the material and the lowest part of the appliance This air space MUST be well vent...

Page 6: ...being used the burners should flame as follows Propane The flames should burn quietly with a blue green colour with no sign of yellow tips Butane Normally on initial lighting a small amount of yellow tipping will occur and then slightly increases as the burner heats up IMPORTANT After installation the appliance MUST be tested for soundness Test ALL burners on high and low flame for flame stability...

Page 7: ...grill does heat up quickly it is recommended that a few minutes preheat be allowed The grill pan should be left in position to protect the base lining and the grill door MUST be left open while the grill is in use A reversible grill pan trivet enables the correct grilling height to be achieved Fast Toasting Trivet in high position Grilling Sausages Trivet in high position Grilling Steak Bacon Triv...

Page 8: ...ance Never check for leaks with a naked flame leak investigation should be carried out using a leak detector spray Maintenance This appliance needs little maintenance other than cleaning All parts should be cleaned using warm soapy water Do not use abrasive cleaners steel wool or cleansing powders When cleaning the burner ring it is essential to ensure that the holes do not become blocked The cont...

Page 9: ...d skirt With a 7mm A F socket unscrew injector from the bottom of the burner mixing tube Replace refit using the reverse procedure Thermocouple removal replacement Shut off gas supply and disconnect gas supply pipe from the unit Remove the hob from the bench top Unscrew the appropriate thermocouple nut next to the burner From the underside of the hob unscrew the appropriate thermocouple nut at the...