IM-P192-02
MI Issue 2
3
EMC directive
The product complies with the Electromagnetic Compatibility Directive
2004 / 108 / EC. A technical file with a reference number of 'UK Supply TVA flowmeter'
supports the Spirax Sarco claim that the product complies with the requirements of
the Directive and the product can be used in Class A (heavy industrial) and Class B
(domestic / commercial areas).
The following conditions should be avoided as they may create interference above
the heavy industrial limits if:
-
The product or its wiring is located near a radio transmitter.
-
Cellular telephones and mobile radios may cause interference if used within
approximately 1 metre (39") of the product or its wiring. The actual separation
distance necessary will vary according to the surroundings of the installation
and the power of the transmitter.
If this product is not used in the manner specified by this IMI, then the protection
provided may be impaired.
1.1 Intended use
Referring to the Installation and Maintenance Instructions, name-plate and Technical
Information Sheet, check that the product is suitable for the intended use / application.
The product listed complies with the requirements of the European Pressure
Equipment Directive 97 / 23 / EC, carries the
mark when so required.
The product falls within the following Pressure Equipment Directive categories:
Product
Group 1
Gases
Group 2
Gases
Group 1
Liquids
Group 2
Liquids
TVA flowmetering
system
DN50 to DN100
-
1
-
-
i) The product has been specifically designed for use on saturated and superheated
steam only which is in Group 2 of the above mentioned Pressure Equipment
Directive.
ii) Check material suitability, pressure and temperature and their maximum and
minimum values. If the maximum operating limits of the product are lower than
those of the system in which it is being fitted, or if malfunction of the product
could result in a dangerous overpressure or overtemperature occurrence, ensure
a safety device is included in the system to prevent such over-limit situations.
iii) Determine the correct installation situation and direction of fluid flow.
iv) Spirax Sarco products are not intended to withstand external stresses that may
be induced by any system to which they are fitted. It is the responsibility of the
installer to consider these stresses and take adequate precautions to minimise
them.
v) Remove protection covers from all connections and protective film from all name-
plates, where appropriate, before installation on steam or other high temperature
applications.