background image

 

Page 46 of 54 

How to Find the Hand Set 

 

If you have misplaced the handset you can page it by pressing the + button 

only on the fire control for around 5 seconds. The handset will flash and make a 

noise to help you to locate it. Once you pick up the TESC it knows you hold it 

and so the sound stops. The flashing and sound will last for 60 seconds each 

time the handset is paged as described. If not found in 60 seconds, page again 

and so on.  

 

NOTE: PRESS “+” Button ONLY , NOT “+” and “-‘ Together as you will 

accidentally break the handset pairing and have to reset handset to 

factory state and pair again (see other parts of the booklet if this 

happens). 

 

 

Pairing the Handset. 

 

WARNING:

 There should be no reason to do this with a new or working fire as 

the pairing has been done at the factory. This is only to be used in the event of 

fitting a new control box or using a new handset. Using these instructions on a 

new fire will erase all of the factory settings. If you are experiencing difficulty 

using the handset on a new fire we suggest reading the above instructions again 

or using the YouTube videos.  

 

DO NOT USE THESE INSTRUCTIONS ON A NEW FIRE OR WORKING FIRE 

 

If either the handset is reset or the gas control has the pairing operation 

buttons operated, the current pairing will be broken and both the two operations 

below will be required to be done to enable a new pairing to be set up. This will 

need a gas engineer to enter the gas controls inside the fire. 

Summary of Contents for FR850-NV

Page 1: ...e the time to read through these instructions and follow them step by step Please quote this serial number when calling to discuss installation and spare part requests The Warranty is valid for 1 Year...

Page 2: ...ce Page 22 Fitting the Logs Page 25 Fitting the Pebbles Page 26 Final Safety Check List Page 27 Commissioning Sheet Page 28 Fire Guards Hearths Page 29 Technical Fault Diagnosis Troubleshooting Page 3...

Page 3: ...on has a minimum flue requirement of 178mm diameter or Class 1 chimney at 2m in length This version needs room ventilation with a 100cm2 air vent to the outside air FR850NV Natural Gas Only This versi...

Page 4: ...de 228407 Remote Transmitter RF868D Countries of Destination The FR850 is CE approved for installation in the following European Countries with I2H Gas 20mBar or I3P Gas 37mBar AT BG CH CZ DK EE ES FI...

Page 5: ...ing test or becoming unreliable This then may require removal of the fire and pipework to rectify the gas pressure Gas Flow Rate NG 0 705 m3 Hour Gas Flow Rate LPG 0 278 m3 Hour Room Ventilation The F...

Page 6: ...NV Check the delivery paperwork and Data Plate inside the fire to confirm which version was purchased by the customer The installation should only be carried out by a GAS SAFE registered engineer and...

Page 7: ...Page 7 of 54 Construction Dimensions FR 850 V FR 850 NV...

Page 8: ...ure these are correct for the property supply This Fire has a battery remote control system and requires only the connection of an 8mm gas supply The remote is operated by a radio frequency remote sys...

Page 9: ...e performance The batteries will last a minimum of 12 months or longer however it is advised to ask you gas installer to replace the batteries on each 12 month service The handset will switch the fire...

Page 10: ...the fire is installed a flue test in accordance with National Regulations should be carried out Any flue damper plate or flue restrictor must be removed or fixed permanently in the fully open positio...

Page 11: ...vacuation of the combustion products is interrupted If the fire shuts itself off do not use the fire and have the flue and fire checked by a suitably qualified person FR 850 V This version of the gas...

Page 12: ...via an isolation valve The fire also includes a pressure test point elbow to test inlet pressure The gas pipe work should be routed into the enclosure via the available access holes If the gas pipe w...

Page 13: ...bble It is advisable to install a solid base inside the fire opening to sit the steel framework supporting the burner unit on to Preparing the Fireplace Opening Above shows the minimum fireplace openi...

Page 14: ...e Fireplace into the Opening Once the fireplace opening has been created the appliance can be lifted into the opening Feed the gas pipe through the chosen hole into the lower burner area ready for con...

Page 15: ...a minimum clearance of 10mm on each side and 10mm at the top This allows minor adjustment This void should be sealed with a suitable fire retardant material to seal the enclosure to the opening Once i...

Page 16: ...54 Without Gather With Gather The gather has a spigot to allow connection to a suitable flue liner The diameter of the gather spigot depends on the model chosen FR850 V 180mm and FR850 NV 130mm See d...

Page 17: ...Page 17 of 54 Once the fire is fixed in place the fire can be finished with plasterboard to create the final look required The gas can now be connected and the fire commissioned...

Page 18: ...The gas line should now be connected to the 8mm inlet isolation valve with built in test point Once connected perform a drop test to ensure no leaks in the pipe work up to the gas appliance Remove th...

Page 19: ...ol is visible Remove the shield from the remote box and switch on the power Refit the remote heat shield Refit the metal heat shield Read the section on lighting the fire and how to operate the remote...

Page 20: ...n the open position to allow gas to flow Remove the screw from the test point within the appliance and connect a manometer With the appliance off check for gas soundness in the supply circuit If there...

Page 21: ...shelf Refit the Vanity Shelf The vanity Shelf is secured by 4x cross headed screws These must be fitted and the shelf fixed in place WARNING If the shelf is left loose and the fire used the vanity wil...

Page 22: ...R850 Log Layout 14 Piece Log Set Fit logs numbered 4 3 Fit logs numbered 9 13 Add the Wool to the burner Add the Wool on top of cut out Do not put wool near the pilot assembly It should be in the cent...

Page 23: ...Page 23 of 54 Add logs numbered 14 17 Add logs numbered 5 8 Add logs numbered 15 11...

Page 24: ...Page 24 of 54 Add logs numbered 16 6 Add logs numbered 10 12 Final layout...

Page 25: ...k 11 pebbles along the front The pebbles must not touch the burner and are positioned on the vanity cover See images below Add the Wool between the pebbles and along the burner bar Do not place any wo...

Page 26: ...completed by the registered engineer who has commissioned the appliance This is to validate the warranty The card must then be given to the customer for postage back to the factory FINAL SAFETY CHECK...

Page 27: ...essure test appliance off mBar 3 Appliance working pressure on High Setting with all other gas appliances in the house operating on full mBar 4 Appliance working pressure on High Setting with all othe...

Page 28: ...of young children the elderly and infirm The installer is to advise the user not to stand too close to the appliance for prolonged periods of time and warn that loose clothing is particularly at risk...

Page 29: ...edure is not followed and the fire is left to run with the wrong gas pressure the fire will 1 Fail to light 2 Light for a few seconds 3 Shut down unexpectedly 4 Have a low flame 5 Have a yellow flame...

Page 30: ...ilot gas slot is clear Pilot lights but does not light main burner Check the pilot flame is heating the thermocouple replace pilot Check that the thermocouple is working replace pilot Check that the g...

Page 31: ...d lead to a hazard Spark Ignition Failure The gap between the pilot electrode and the pilot should be 3 5 4 5mm and normally adjustment is not necessary the electrode is very brittle The spark should...

Page 32: ...ng heat damage is not covered by the warranty Remote Control Components The remote control used on this fire has only a small number of components to function a A black remote box gas control valve b...

Page 33: ...ration is as per the manufacturer s instructions That the gas fire burner unit correctly cross lights within 10 seconds A pressure drop test to verify that there are no gas leaks That the electronic i...

Page 34: ...s on this fire Servicing Procedure Turn off the gas fire and allow time for it to cool Remove the vanity cover as shown on page 18 Turn off the gas supply at the isolation tap within the fire INJECTOR...

Page 35: ...ling to order spare parts you will be requested to provide both the serial number of the fire and gas safe registration number of the person who will carry out the repairs The serial number is shown o...

Page 36: ...Page 36 of 54...

Page 37: ...ing to discuss installation and spare part requests The Warranty is valid for 1 Year from date of delivery To register the appliance complete the warranty card supplied and return to Spirit Fires Limi...

Page 38: ...Information Page 40 Start Shutdown Instructions Page 49 Using the Manual Switch if fitted Page 50 Replacing the Batteries Page 51 Cleaning Instructions Page 52 Fire Guards and Hearths Page 53 Warrant...

Page 39: ...ite normal and any odours should disperse within a few hours of operation Do not use the fire when decorating or burning scented candles This will cause additional smells and staining on walls For som...

Page 40: ...t is more likely the handset is not being pressed correctly If the main burner or pilot light is extinguished during lighting do not attempt to re light the pilot within three minutes Quick Start User...

Page 41: ...e unlock light will happen upon touching When the word pilot appears at the bottom left hand corner of the display immediately release the power button A second flash of the unlock light and a longer...

Page 42: ...fit a new set of alkaline batteries like Duracell o c that the small isolation switch on the gas control in the top left corner is in the ON position I and not the OFF position O Grasp the handset in...

Page 43: ...can be seen on YouTube use your internet browser to visit YouTube page and within YouTube search for TESC GAS CONTROL Setting Up The Handset The handset comes paired to the black box so does not need...

Page 44: ...gate through the menu set moves to the next parameter and Mode move back to the previous parameter and change the display parameter Setting the display for 12 or 24 Hour display The H indicates that i...

Page 45: ...Fire Control Advanced settings Menu In the event that you may want to change the other preset settings of the control features Do not do a long press and hold above but a normal short press and relea...

Page 46: ...his happens Pairing the Handset WARNING There should be no reason to do this with a new or working fire as the pairing has been done at the factory This is only to be used in the event of fitting a ne...

Page 47: ...the handset This can only be done after the handset has been made free to pair as shown in step 1 above Ensure all the batteries are fitted correctly and with the power isolator slide switch on the TE...

Page 48: ...nlock as described previously and press the mode button as many times as necessary until the word MAN and the Zzz symbols are flashing at the top of the display Press and release the set button and th...

Page 49: ...o the actual temperature displayed on the handset i e the room ambient temperature around the handset The handset will then adjust the fire flame up and down depending on the required temperature If t...

Page 50: ...e batteries involves removal of the vanity cover and heat shields It is strongly advised to leave this task to a gas safe engineer to perform The best time to change the batteries is during the annual...

Page 51: ...te isolator switch to the left away from the On position symbol 0 Don t forget to switch it back on in the winter Cleaning Instructions Before cleaning the appliance turn off the gas fire and allow it...

Page 52: ...urner unit DO NOT USE THE APPLIANCE contact your installer to ensure the gas fire is still safe and functions correctly Warning Fire Guards Hearths This appliance is not fitted with an integral guard...

Page 53: ...full details of the GAS SAFE engineer who installed the appliance We may also request a copy of the installation receipt Failure to supply details of the Registered Engineer who installed the applian...

Page 54: ...ritfires co uk sales spiritfires co uk This revision is dated on the 14 10 2015 The information supplied in this manual is correct at the time of publication There may be changes made in future as we...

Reviews: