4-120
Flow-X─ Function Reference
Flow-X General functions - fxAPI_RD60F_NGL_LPG
fxAPI_RD60F_NGL_LPG
Description
Relative Density (T, P) <--> Relative Density (60°F, Pe)
This function converts the relative density value at the observed temperature and pressure to the
relative density value at 60°F and the equilibrium pressure or vice versa.
The temperature correction is according to API MPMS 11.2.4:2007 (GPA TP-25 / GPA TP-27), while the
pressure correction is according to API MPMS 11.2.2:1984.
The calculation of the equilibrium pressure is according to GPA TP-15 (API MPMS 11.2.2
Addendum:1994).
Compliance
API MPMS 11.2.4: Temperature Correction for the Volume of NGL and LPG Tables 23E, 24E,
53E, 54E, 59E & 60E, September 2007
GPA TP-27: Temperature Correction for the Volume of NGL and LPG Tables 23E, 24E, 53E,
54E, 59E & 60E, September 2007
GPA TP-25: Temperature Correction for the volume of Light Hydrocarbons – Tables 24E and
23E, 1998
API MPMS 11.2.2 - Compressibility Factors for Hydrocarbons: 0.350 - 0.637 Relative Density
(60°F/60°F) and -50°F to 140°F Metering Temperature - Second Edition, October 1986
API MPMS 11.2.5: A Simplified Vapor Pressure Correlation for Commercial NGLs, September
2007
GPA TP-15: A Simplified Vapor Pressure Correlation for Commercial NGLs, September 2007
(also covers GPA TP-15 1988)
API MPMS 11.2.2 Addendum : Compressibility Factors for Hydrocarbons: Correlation of
Vapor Pressure for Commercial Natural Gas Liquids (same as GPA TP-15:1988)
Function inputs
Name
Remark
EU
SW tag
Range
Defaul
t
Name
Optional tag name, tag description
and tag group
Input
relative
density
Depending on the conversion
method this represents the relative
density either at the observed
temperature and pressure or at 60
°
F and the equilibrium pressure
-
0..0.75
0
Observed
temperature
Temperature at which the relative
density is observed
°F
-
100..300
60
Observed
pressure
Pressure at which the relative density
is observed
psia
-
10..2500
0
API 11.2.4
rounding
0: Disabled
The calculations are performed
with full precision and the
output values are not rounded
1: Enabled
The input and output values are
rounded as defined in the
standard
API1124RN
D
0
API 11.2.2
rounding
0: Disabled
The calculations are performed
with full precision and the
API1122RN
D
0
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...