Flow-X─ Function Reference
4-127
Flow-X General functions - fxAPI_Table5_1980
Function
outputs
Remark
EU
SW tag
Alarm
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: No convergence
-
STS
FIOOR
CALCERR
NOCONV
1
API at 60 °F
API gravity at 60°F
°API
API
0
CTL
Volume correction factor for
temperature.
-
CTL
1
K0
Actual value of constant K0 used
for CTL calculation
-
K0
0
K1
Actual value of constant K1 used
for CTL calculation
-
K1
0
K2
Actual value of constant K2 used
for CTL calculation
-
K2
0
Alpha
Thermal expansion factor
1/°F
ALPHA
0
Product
When input 'Product' is 'B - Auto
select', then the output is set to
the actual selected product of
table 5B (enumerative value as
defined for input 'Product'), else
the output is set equal to input
'Product'.
-
PRDCUR
0
Calculation out
of range
With respect to the standard
the input values are:
0: In Range
1: Out of Range
-
OOR
0
Calculations
The calculations are in full or partial compliance with the standard depending on input ‘API 2540
rounding’.