4-148
Flow-X─ Function Reference
Flow-X General functions - fxAPI_Table53_1980
fxAPI_Table53_1980
Density (T) --> Density (15°C)
This function converts a density value at the observed temperature to the density value at 15°C.
The temperature conversion is according to API-2540, Tables 53A (Generalized Crude Oils) and 53B
(Refined Oil Products) and API MPMS 11.1 Chapter XIV Table 53D: 1984 (Lubricating Oils).
The function provides the option to correct for readings taken from a hydrometer as specified in the
API-2540 standard.
Compliance
API MPMS 11.1 Volume X (API Standard 2540) - Table 53A - Generalized Crude Oils,
Correction of Observed Density to Density at 15°C - First Edition, August 1980
API MPMS 11.1 Volume X (API Standard 2540) - Table 53B - Generalized Products,
Correction of Observed Density to Density at 15°C - First Edition, August 1980
API MPMS 11.1 Volume XIV - Table 53D - Generalized Lubricating Oils, Correction of
Observed Density to Density at 15°C - January 1982
Function inputs
Remark
EU
SW tag
Range
Default
Name
Optional tag name, tag
description and tag group
Observed density
Density at observed
temperature
kg/
m3
0..1300
0
Observed
temperature
°C
-100..200
15
Product
1: A - Crude Oil
2: B - Auto select
Selection based on density at
15 °C
3: B - Gasoline
4: B - Transition Area
5: B - Jet Fuels
6: B - Fuel Oil
7: D - Lubricating Oil
PRDTYP
1
API2540 rounding
0: Disabled
The calculations are
performed with full
precision.
A convergence limit of
0.000001 kg/m3 will be
applied for the iterative
calculations.
1: Enabled
API-2540 rounding and
truncating rules are
applied.
A convergence limit of
0.05 kg/m3 will be
applied as defined in the
standard.
APIROUND
0
Hydrometer
correction
0: Disabled
1: Enabled
HYDROCOR
0
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...