Flow-X─ Function Reference
4-153
Flow-X General functions - fxAPI_Table54_1952
fxAPI_Table54_1952
Density (15°C) --> CTL
This function determines the volume correction factor for temperature CTL from the relative density
value at 15°C and the observed temperature according to the API 1952 Table 54.
Compliance
ASTM-IP Petroleum Measurement Tables, Metric Edition, Metric Units of Measurement,
1952
Boundaries
Table 54 contains values for the following range:
Input value
Normal Range
EU
Density at 15 °C
500 .. 1100
kg/m3
Observed temperature
-50 .. +150
°C
Note that the table does not cover the full range, e.g. for a Density at 15 °C of 500 kg/m3the table only
specifies values between -50 .. 55 °C
Function inputs and outputs
Function inputs
Remark
EU
SW
tag
Range
Default
Name
Optional tag name, tag
description and tag group
Density 15 °C
Specific gravity at 60°F
Kg/m3
0..1300
0
Observed
temperature
°C
-100..200
15
Function outputs
Remark
EU
SW tag
Alarm
Fallbac
k
Status
0: Normal
1: Input argument out of range
-
STS
FIOOR
CTL
Volume correction factor for
temperature.
-
CTL
1
Calculation out of
range
With respect to the standard the
input values are:
0: In Range
1: Out of Range
-
OOR
0
Calculations
The table values are the standard, so no calculations are involved. The function performs an
interpolation between the table values that correspond to the input specific gravity and input
temperature.
In case the combination of input values ('Specific gravity 60 °F' and Observed temperature') is not
covered by the table, the output 'CTL' is set to 1 and output 'Calculation out of range' is set to 1.
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...