4-180
Flow-X─ Function Reference
Flow-X General functions - fxBatchWatch
fxBatchWatch
Description
The function 'remembers' that a condition has been valid during a batch.
A typical example is a transmitter that was overridden with a keypad value.
Inputs and outputs
Function
inputs
Remark
EU
SW tag
Range
Default
Name
Name used for tag-prefix and
retentive storage.
Condition
0:
Condition is not valid
<>0:
Condition is valid
Enabled
0: Disabled
1: Enabled
EN
Reset
command
Trigger to reset the batch.
At a batch reset the current
watched value is stored in the
previous value and the current
watched value is reset to 0
Identification
Batch identification.
Can be any string of maximum 255
characters long.
If multiple identifications need to
be stored for future referral, e.g.
the batch number, the ship name
and the nomination number, then
the individual strings should be
concatenated with an "." character
in-between.
ID
Function outputs
Remark
EU
SW tag
Alarm
Fallback
Current watch
Indicates whether or not the
condition has been valid during the
current batch:
0: Not valid
1: Valid
CB
0
Previous watch
Indicates whether or not the
condition has been valid during the
previous batch:
0: Not valid
1: Valid
PB
0
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...