4-242
Flow-X─ Function Reference
Flow-X General functions - fxISO6976ex_1995_M
Function
inputs
Remark
EU
Default
User-defined
molar mass
Array of molar masses of the additional user-definable
components. This should be the molar mass corresponding
to the current ‘Molar mass table method’.
Note: This array should be exactly as long as the user-
defined composition array.
kg/kmol
0
User-defined
summation
factor
Array of summation factor values of the additional user-
definable components.
Note: The input values have to correspond with the
metering conditions of input ‘Reference conditions. This
array should be exactly as long as the user-defined
composition array.
-
0
User-defined
superior
calorific value
(SCV)
Array of Superior Calorific Values of the additional user-
definable components. This should be the SCV
corresponding to the current reference conditions.
Note: the input values have to correspond with the
conditions as defined by input ‘Reference conditions. This
array should be exactly as long as the user-definable
composition array.
KJ/mol
0
User-defined
inferior
calorific value
(ICV)
Array of Inferior Calorific Values of the additional user-
definable components. This should be the ICV
corresponding to the current reference conditions.
Note: the input values have to correspond with the
conditions as defined by input ‘Reference conditions. This
array should be exactly as long as the user-definable
composition array.
KJ/mol
0
Function outputs
Remark
EU
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: Mole fractions do not add up to 1.0 +- 0.0001
Superior calorific
value
Real superior calorific value on volume basis at the
reference conditions of temperature and pressure
MJ/m3
0
Density
At the reference conditions of temperature and
pressure
kg/m3
0
Compressibility
-
1
Relative density
-
0
Molar mass
kg/kmol
0
Superior calorific
value
Real superior calorific value on mass basis at the
reference conditions of temperature and pressure
MJ/kg
0
Superior calorific
value
Real superior calorific value on mole basis at the
reference conditions of temperature and pressure
MJ/kmol
0
Inferior calorific
value
Real inferior calorific value on volume basis at the
reference conditions of temperature and pressure
MJ/m3
0
Inferior calorific
value
Real inferior calorific value on mass basis at the
reference conditions of temperature and pressure
MJ/kg
0
Inferior calorific
value
Real superior calorific value on mole basis at the
reference conditions of temperature and pressure
MJ/kmol
0
Wobbe index
MJ/m3
0
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...