Flow-X─ Function Reference
4-251
Flow-X General functions - fxNX19_1962
Function outputs
Remark
EU
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
Note: value 1 is also reported when one of the
intermediate results is out of limit.
Compressibility factor
Compressibility factor at the observed temperature
and pressure (Zf)
-
1
Base compressibility
factor
Compressibility factor at 60 ᵒF and 14.7 psia (Zb)
-
1
Super-compressibility
factor
Super-compressibility Fpv. Refer to section
Calculations for ist definition.
-
1
Range
0: All input values are within the 'Normal Range'
1: One or more input values are outside the 'Normal
Range
-
0
Calculations
The AGA-NX-19 standard specifies the calculations of the super-compressibility Fpv, which is defined as
follows:
Where:
Fpv
Supercompressibility
Zb
Compressibility at base conditions of 60 ᵒF and 14.7 psia
Zf
Compressibility at flowing conditions, i.e. at the input temperature and pressure
The definition of the base compressibility factor when applying the AGA-NX19:1962 method for
custody transfer is given in chapter 2 of [Miller:1996].
Where T = Tadj/500 with Tadj calculated in accordance with the AGA NX-19:1962 standard
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...