Flow-X─ Function Reference
4-253
Flow-X General functions - fxNX19_M
shall be at the applicable reference
conditions of pressure and temperature.
Gross heating value
At the applicable reference conditions of
pressure and temperature
Only required when the ‘PTB G9
correction’ is enabled.
MJ/m3
0..100
0
Nitrogen
mol/mol
0..1
0
Carbon dioxide
mol/mol
0..1
0
PTB G9 correction
Determines if the AGA-NX-19-mod /
AGA-NX-19-mod.BR.KORR.3H is used
instead of the AGA-NX-19-1962 standard
calculation.
0: Disabled
1: Enabled
-
1
Function outputs
Remark
EU
Fallback
Status
0: Normal
1: Input argument out of range
2: Calculation error
3: No convergence
Note: value 1 is also reported when one of the
intermediate results is out of limit.
Compressibility factor
-
1
Range
0: All input values are within the 'Normal Range'
1: One or more input values are outside the 'Normal
Range
-
0
Calculations
The calculations are as specified in the standards.