4-310
Flow-X─ Function Reference
Flow-X General functions - fxVCone_C
Expansion Factor
Range
The McCrometer reference document states that
for gas applications the expansion factor should
not get below 0.84
0: Expansion factor is in valid range
1: Expansion factor is out of valid range
-
0
Calculations
The flow calculation is as specified in the McCrometer reference document.
The downstream to upstream correction (and vice versa) for pressure, temperature and density are as
specified for function 'ASME MFC-3M Orifice'.