Flow-X─ Function Reference
3-45
Flow-X General functions - fxAPI_Dens15C_1980
in all cases
3: Enabled with 5 decimal places
API-2540 rounding and
truncating rules are
applied, and, in case of
conversion method 2
(standard to observed),
the CTL value has 5
decimal places in all
cases.
Note: although not strictly
in accordance with the
standard, this option is
more commonly used
than option 'Enabled for
computational value'
Note: for conversion type 1
‘From observed to standard
conditions’ the CTL factor is
rounded to 6 decimal places
when input ‘API 2540 rounding’
> 0, as in accordance with table
53.
Hydrometer
correction
Only applies for conversion
method
‘1: From observed to standard
conditions’
0: Disabled
1: Enabled
-
HYDROCOR
0
API 11.2.1M
rounding
0: Disabled
The calculation of the
compressibility factor F is
performed with full
precision.
1: Enabled
API-MPMS 11.2.1M
rounding and truncating
rules are applied. The
compressibility factor F is
rounded to 3 decimal
places as specified in the
standard.
-
API1121RND
0
Equilibrium
pressure
The equilibrium pressure is
considered to be 0 bar(g) for
liquids which have an
equilibrium pressure less than
atmospheric pressure (in
compliance with API MPMS 12.2
par. 12.2.5.4)
bar(g)
EQUIPRES
0..150
0
Conversion
method
1: From observed to standard
conditions
2: From standard to observed
conditions
CONVERSIO
N
1
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...