Flow-X─ Function Reference
4-87
Flow-X General functions - fxAPI_Dens20C_NGL_LPG
precision and the
output values are not
rounded
1: Enabled
The related values are
rounded as defined in
the standard
Equilibrium
pressure mode
1: Use Input
The value of input
'Equilibrium pressure
value' is used for the
calculation of CPL
2: GPA TP-15
The equilibrium
pressure is calculated in
accordance with GPA
TP-15
EQUIPMODE
2
Equilibrium
pressure value
Only used when input
'Equilibrium pressure mode'
is set to 0.
The value will be used for the
calculation of the CPL
bar(a)
EQUIPINP
0
GPA TP-15
rounding
0: Disabled
Full precision (no
rounding and truncating
applied)
1: Enabled
Rounding as defined in '
GPA TP15:1988 / API
MPMS 11.2.2
Addendum':1994
-
TP15RND
0
P100 Correlation 0: Disabled
The standard correlation
is commonly used for
pure products such as
propane, butane and
natural gasoline. It only
requires the relative
density and the
temperature to calculate
the vapor pressure
1: Enabled
The improved correlation
requires the vapor
pressure at 100°F (37.8
°C). This method is better
suited for varied NGL
mixes Where different
product mixes could have
the same specific gravity
but different equilibrium
pressures.
-
P100CORR
0
Vapor pressure
at 100°F
bar(a)
EQUIP100F
0..200
0
Conversion
method
1: From observed to
standard conditions
2: From standard to
observed conditions
CONVMETH
1
Summary of Contents for flow-x
Page 1: ...Function Reference Certified flow calculations Flow and batch calculations Worksheet functions...
Page 331: ...Flow X Function Reference 5 331 Flow X IO Functions fxPT100Table...
Page 349: ...Flow X Function Reference 6 349 This page is intentionally left blank for user notes...
Page 350: ...6 350 Flow X Function Reference This page is intentionally left blank for user notes...