background image

 

 1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORIGINAL INSTRUCTIONS 

OPERATING AND MAINTENANCE 

MANUAL 

 

MADE IN AUSTRALIA 
BY 
SPITWATER AUSTRALIA PTY LTD  
953 METRY STREET 
NORTH ALBURY NSW 2640 
AUSTRALIA 

 

 

 

 

WARNING: Read and understand this instruction manual before operating this 
unit and retain for future reference.  

Failure to follow operating, safety and maintenance instructions outlined in this 
manual releases the manufacturer from any responsibility for any accidents or 
damage incurred and may render any warranty void. 

 

PETROL HOT WATER  
HIGH PRESSURE 
CLEANER 

 
 
 
 
 
 
 
 

MODEL NO: 

SHW90 (SW21200PE) 

Summary of Contents for SHW90

Page 1: ...and understand this instruction manual before operating this unit and retain for future reference Failure to follow operating safety and maintenance instructions outlined in this manual releases the manufacturer from any responsibility for any accidents or damage incurred and may render any warranty void PETROL HOT WATER HIGH PRESSURE CLEANER MODEL NO SHW90 SW21200PE ...

Page 2: ...accordance with the recommendations and safety precautions detailed in this manual All Spitwater high pressure cleaners undergo rigorous safety and operational tests before being dispatched into the market however it is still imperative that prior to use all operators have read and understood all information and instructions provided and are aware of possible hazards Spitwater high pressure cleane...

Page 3: ...60 Ah CCA 520 A PUMP MODEL WS202 N A N A N A OIL TYPE 15W 40 OIL CAPACITY 1 1 L OTHER DETERGENT BOTTLE CAPACITY 10 N A L BURNER PRESSURE 11 BAR VALUES DETERMINED AS PER AS NZS 60335 2 79 SOUND PRESSURE LEVEL Lp 95 N A 3 0 N A N A N A N A N A dB A UNCERTAINTY Kp 3 9 dB A SOUND POWER LEVEL Lw UNCERTAINTY Kw 103 dB A REACTION FORCE ON SPRAY GUN 68 93 N REACTION TORQUE ON SPRAY GUN 15 80 Nm VIBRATION ...

Page 4: ...ential injury if not cautious Their meaning is listed next to them for your attention CAUTION Hot surface Do not touch DESCRIPTION OF SYMBOLS IMPORTANT SAFETY INSTRUCTIONS AND PRECAUTIONS WARNING This high pressure cleaner shall only be used by persons instructed in its use and who have been authorized to do so Before using this high pressure cleaner please pay particular attention to the followin...

Page 5: ...y labels PETROL TANK CHEMICAL TANK WATER INLET CONNECTOR SERIAL LABEL TRIGGER HIGH PRESSURE HOSE MOUNTING HOLES PRESSURE HIGH LOW HIGH PRESSURE WATER OUTLET CONNECTOR DIESEL INLET TEMPERATURE ADJUSTMENT DUAL LANCE PRESSURE GAUGE CHEMICAL FLOW ADJUSTMENT ENGINE SWITCH HOUR METER OIL ALERT INDICATOR ISOLATOR SWITCH EMERGENCY STOP BURNER ON OFF BUTTON ...

Page 6: ...ly authorized to do so DO NOT operate the unit without appropriate personal protective equipment PPE 2 FIRE PREVENTION Store flammable fluids in approved containers and cabinets away from sparks and heat To avoid fire be alert for leaks of flammable substances from hoses and lines The exhaust gas muffler is very hot To prevent a fire do not expose dry grass mowed grass oil or any other combustible...

Page 7: ...omponents e g muffler muffler cover chimney and engine body during operation and after the engine has been shut off 6 CHEMICAL HAZARD In the event of accidental contact with cleaning detergent battery acid or oil follow instructions provided by the manufacturer and or product retailer and wash it off immediately with clean running water Wear rubber gloves to avoid personal injury during chemical h...

Page 8: ... user is subject to very strong recoil forces and torque There is a risk of high pressure water jet injury Never aim the jet at yourself other people or animals as this could result in serious injuries or even death There is a risk of electrocution Never aim the water jet at the unit itself or other live electrical equipment as this could result in serious injury or even death Depending on the app...

Page 9: ...e of original accessories and spare parts available through Spitwater and its extensive dealer network Never use a nozzle size other than that specified in the technical data Using the wrong size nozzle could damage the unit Keep flammable materials away from and do not place anything on the unit while it is running Pressure regulating valve This unit is equipped with a pressure regulating valve w...

Page 10: ...d in order to prevent it from sliding or falling 4 If transporting the unit make sure there is no possibility for the temperature to be at or below 0 C If it is necessary to transport the unit at or below 0 C contact your authorized Spitwater service agent for advice 5 When not in use the unit must be stored in a dry building where there is no possibility for the temperature to be at or below 0 C ...

Page 11: ... position before operating Do not operate on an uneven surface or on loose gravel 5 The engine and exhaust becomes very hot during operation Keep the unit at least 1metre 3 feet away from buildings or other equipment during operation ASSEMBLY INSTALLATION GUIDE 6 Replace the red oil travel plug fitted on the pump with the yellow dipstick supplied in the accessories bag 7 Check the oil level in the...

Page 12: ... do not interchange during assembly Add nozzle shield after nozzle assembly Refer diagram below 9 LANCE TRIGGER GUN HIGH PRESSURE HOSE ASSEMBLY Connect the lance to the spray gun by an in built quick release coupling Connect the high pressure hose fitting to the spray gun Do not over tighten Connect the quick release adaptor to the high pressure hose fitting Do not over tighten ...

Page 13: ...r service agent if found Open the water supply and fill the water tank The float valve will automatically stop the water flow when the water tank is full Water that has flowed through backflow preventer is considered to be non potable non drinkable For suction supply non pressure water supply other than potable water mains contact your authorized Spitwater service agent for advice High pressure ho...

Page 14: ... THIS UNIT as using any other fuel will create a risk of explosion and damage to the unit Remove the DIESEL tank cap and fill the diesel tank with clean filtered diesel ONLY USE CLEAN DIESEL IN THIS UNIT as using any other fuel will create a risk of explosion and damage to the unit DIESEL FUELLING POINT PETROL FUELLING POINT ...

Page 15: ...the engine starts release the engine switch allowing it to return to the ON position NOTE If the engine fails to start within 5 seconds release the engine switch and wait at least 10 seconds before operating the starter again Using the electric starter for more than 5 seconds at a time will overheat the starter motor and can damage it COLD START 1 To start a cold engine pull the choke knob to the ...

Page 16: ...sure gauge matches the value on the data plate and in the technical data Also check that when the trigger is released the pressure shown on the gauge returns to zero 1 To activate high pressure turn the lance handle clockwise and pull the trigger and to activate low pressure turn the lane handle anti clockwise 1 If hot water is required press the burner start button I USAGE TIPS Use the unit as ne...

Page 17: ...is required it CAN BE USED IN LOW PRESSURE ONLY 3 Open the chemical injector by turning the knob anti clockwise until the desired affect is reached When the trigger is pulled water mixed with detergent will be sprayed 4 Never allow sprayed detergent to dry on the cleaning surface as this may damage the surface TO STOP 1 Close the chemical injector by turning it clockwise until it stops 2 Turn the ...

Page 18: ...or switch to OFF position 5 If the unit is to be left unused for an extended period be sure to clean the detergent line by running the water through it and dropping the detergent line into a container of clean water ON OFF ...

Page 19: ...t 6 There are a number of important components that have been set and sealed at the factory Never under any circumstances tamper with modify or adjust these settings 7 Make sure this unit is regularly serviced by an authorized Spitwater service agent according to the servicing requirement outlined in this booklet To maintain this unit in peak working condition during its operating life it is neces...

Page 20: ...and contamination Check for any service due based on USAGE VS SERVICE FREQUENCY Table A CHECKS DURING UNIT RUN Check proper function of burner switches pressure gauge emergency stop and temperature control Check for water leaks at high pressure hose fittings Check pressure gauge to show working pressure as per Technical data sheet when the trigger is in ON position Color of exhaust fumes Dark fume...

Page 21: ...REQUENCY TABLE A Usage vs Service Frequency Time interval for checks and replacement listed above are for units subjected to normal operating conditions Should the unit be subjected to abnormal conditions eg heavy use dirty water extreme temperatures or conditions etc times should be reduced accordingly ...

Page 22: ...f the pump Make sure the level is between min max level notches on the dipstick or is level with the indicator on the sight glass Ensure the unit is on a flat surface Remove the oil level dipstick and wipe it clean Fully insert the oil level dipstick and then remove it to check the oil level Acceptable oil level is between upper and lower limit ENGINE OIL CHECK PUMP OIL CHECK ...

Page 23: ...rvice agent Water leaking from pump Contact Spitwater service agent Oil leaking from pump Contact Spitwater service agent Engine does not start operate correctly Refer to engine instruction book Contact Spitwater service agent For all PETROL ENGINE specific troubleshooting refer to the enclosed HONDA manual TROUBLESHOOTING GUIDE If the fault cannot be identified or corrected using the below list o...

Reviews: