Installation
Requirements to the air supply
The pneumatic drill works optimally at an operating pressure of 6 bar, measured at the air inlet. The distance
from the air supply to the machine has to be adjusted to the application conditions on site.
We recommend installing an oiler or a maintenance unit upstream the machine for compressed air
preparation. Use acid and resin-free lubricating oil, like SAE 5W - SAE 10W.
Attention! Do not use viscous oil.
Use an antifreeze lubricant during winter time or when the compressed air is very moist, e.g.:
“Kilfrost”
or “Kompranol N74”.
The supplied compressed air has to be free of:
Foreign particles,
humidity.
Pay attention that all hoses:
Have a cross section being large enough,
do not have any restrictions or kinks,
are designed for a minimum operating pressure of 6 bar,
are replaced regularly at preventative maintenance,
have an oil resistant inner surface and an abrasion-resistant outer surface,
are proved and specified to be non-conductive when being used next to electric conductors.
Always use hoses, lubricating oil and antifreeze lubricants, which meet the local safety requirements for use
in areas exposed to explosion hazards.
Connecting the air supply to the pneumatic drill
Remove the locking cap from the air connection 3. Connect the pneumatic hose (not contained in the scope
of delivery).