background image

 

 

 

Press the 

Upload

 button and wait until the operation is completed: 

 

 

Switch off the device and close the 

Measuring Center

 

Switch  on  the  device,  wait  until  it  is  completely  booted  and  start  the 

Measuring  Center

 

software.  In  case  of  successful  connection  in 

Next-Lab  Wi-Fi  Config

  region  the  module  status 

will  switch  to 

Wi-Fi  Module  Connected

,  and  in

  IP 

field  the  IP  address  of  the  device  in  the 

network will be shown. 

 

Please note that: 

 

The  Wi-Fi  module  might  require  some  time  (1-2  minutes)  for  connecting;  for  refreshing  the 
connection status press 

Update device list

 button.

  

 

If  the  module  is  unable  to  connect  within  2  minutes,  it  goes  into  sleep  mode,  and  for 
reconnecting the module the device has to be restarted. 

 

In some cases for successful connection the Wi-Fi access point/PC/smartphone/tablet PC should 
be restarted. 

Configuration according to the Smart-Config technology 

The  Smart-Config  technology  allows  remotely  configuring  the  Wi-Fi  module  of  Next-Lab  devices  using 
Android/iOS-based tablet PC/smartphone. For using Smart-Config technology you will need a 

Measuring 

Center

 for

 Android/iOS

 application. The application can be downloaded from the corresponding stores 

(Google Play, App Store) or from “Support” section of the 

www.spl-lab.ru

 website (only for Android). 

It is important to note that the tablet PC/smartphone, which is being used for configuration of the Next-
Lab device according to the Smart-Config technology, should be connected to the same wireless network, 
to which it is planned to connect the device. In other words, configuration of the device for connecting it 
to tablet PC/smartphone, which has tethering mode (hotspot) enabled, is possible only through another 
device (one more tablet PC or smartphone). 

Summary of Contents for Next-Lab

Page 1: ...2015 Spl Lab 31 10 2015 Connection to Next Lab devices via the wireless network ...

Page 2: ...of the Wi Fi module using PC 3 Configuration according to the Smart Config technology 4 Configuration of the Wi Fi module through the interface in Next LCD device 6 Setting of a PC tablet PC smartphone for operation with the device 7 Setting the PC 7 Setting of a Tablet PC smartphone 8 ...

Page 3: ...s network only as a client Wi Fi module cannot serve as the hotspot for other devices it is impossible to connect to it as a client The module can be directly connected to Wireless hotspot router Smartphone tablet PC in tethering mode hotspot PC in tethering mode hotspot Connection to the internet via Wi Fi when in tethering mode hotspot is impossible Connection with the device that has Wi Fi modu...

Page 4: ...g Center for Windows drivers from Support section at www spl lab ru website or from the CD that is included into the delivery set Switch on the Next Lab device and wait until it is completely booted the Power indicator glows constantly Connect the device to the PC and wait until drivers are installed Launch the Measuring Center for Windows software Go to Config tab of the program If you did everyt...

Page 5: ...Fi access point PC smartphone tablet PC should be restarted Configuration according to the Smart Config technology The Smart Config technology allows remotely configuring the Wi Fi module of Next Lab devices using Android iOS based tablet PC smartphone For using Smart Config technology you will need a Measuring Center for Android iOS application The application can be downloaded from the correspon...

Page 6: ...d Gateway fields will be filled in automatically Activating the mode on the device Activate the Smart Config mode on your Next Lab device It can be done in three ways On the device switch on the device simultaneously pressing button 1 pressed on wait until the power indicator blinks 5 times On the Next LCD select a Start Smart Config in the Wi Fi Settings configuration section of the Next LCD devi...

Page 7: ...ns of Next LCD device microcode If you are unable to enter Wi Fi Settings mode on your device download the latest microcode version from Support section of the www spl lab ru website and run the update for your device according to the instruction given in the archive with firmware upgrade Start the device and wait until it is completely booted Enter Wi Fi Settings mode by pressing 2 button Option ...

Page 8: ... exchange data via USB and Wi Fi at the same time Disconnect the device from USB port of a PC to enable the device connection to the wireless network Setting the PC Switch on the Next Lab device and wait until it is completely booted the Power indicator glows constantly Connect the device to a PC using USB cable Launch the Measuring Center for Windows software Go to Config tab of the program Selec...

Page 9: ...he Wi Fi access point PC smartphone tablet PC should be restarted Setting of a Tablet PC smartphone Switch on the Next Lab device and wait until it is completely booted the Power indicator glows constantly Launch the Measuring Center for Android iOS on your tablet PC smartphone Open the Config tab from the main menu of the program Skip the next step if you know IP address and port of the device Pr...

Reviews: