Performer s800 – Quickstart
Performer s800 – Quickstart
2
3
Voltage Selection:
Fuse:
1. Remove Fuse Holder
2. Exchange Fuses
3. Flip Over 4. Reinstall
AVIS: RISQUE DE CHOC ÉLECTRIQUE • NE PAS OUVRIR
RISK OF ELECTRIC SHOCK
D O N O T O P E N
C AU T I O N
X L R W I R I N G
Pin 1 = GND
Pin 2 = Hot (+)
Pin 3 = Cold (–)
Minimum Load: 4
Ω
Minimum Load: 4
Ω
Minimum Load: 8
Ω
Serial
Number
Made in Germany
~ 115V AC / ~230V AC, 50 Hz / 60 Hz, P max. 855VA
Mono
3,5mm
Jack
INPUT L
IN
PU
T L
AMP CTL
AMP CTL
Connect to SPL
Preamplifier/DAC
AMP CTL output
for remote
power on/off.
INPUT R
IN
PU
T R
SPE
AK
ER O
UTP
UT R | B
RID
GE M
OD
E (–)
SPEAKER OUTPUT R | BRIDGE MODE (–)
SPE
AK
ER O
UTP
UT L | B
RID
GE M
OD
E (+)
SPEAKER OUTPUT L | BRIDGE MODE (+)
BRIDGE MODE
+
–
–
–
+
0 -5.5
-5
-
4.5
-4
-3.5
-3
-2.
5
-
2
-1
.5
-
1
-
0.5
T
RI
M
T
HR
U
T
HR
U
I
NP
UT
I
NP
UT
0 -5.5
-5
-
4.5
-4
-3.5
-3
-2.
5
-
2
-1
.5
-
1
-
0.5
T
RI
M
230V AC: T 4 A L 250 V
115V AC: T 8 A L 250 V
Performer
s800
BRIDGE MODE
In Bridge Mode
INPUT R is not
used.
In Bridge Mode
use INPUT L
only.
Note: Trims are deactivated
+
BRIDGE MODE
BRIDGE MODE
ON
OFF
EN
DE
Start up
Read the security advices on page 8!
Make sure that the selected mains voltage of the Performer s800 is according to
the mains voltage of your region.
Make sure that the mains switch on the rear of the Performer s800 is set to Off
(Off = O / ON = I).
Connect the supplied power cord to the Performer s800 and an appropriate
mains socket outlet.
If the supplied power cord does not match your mains socket outlet, please contact your dealer.
Turn off all devices you wish to connect to the Performer s800.
If you own a SPL Director or a SPL Phonitor x you can switch both units between
standby and operation together. Therefore connect the AMP CTL of the Director
or Phonitor x with a mono mini jack cable to the AMP CTL of the Performer s800.
Mono mini jack cable not included in the scope of delivery.
Warning: Use only SPL Phonitor x or SPL Director for amplifier control.
Never connect other devices to the AMP CTL jack.
If you want to run the Performer s800 in
stereo mode
,
continue with
7
.
If you want to run the Performer s800 in
bridge mode (mono)
,
continue with
10
on the next page.
Stereo mode operation
Make sure that the BRIDGE MODE switch is set to OFF.
Please connect the outputs of your preamplifier to the inputs (INPUT L and
INPUT R) of the Performer s800. Please use appropriate audio cables (XLR).
Audio cables not included in the scope of delivery.
Connect the Performer s800 with speaker cables to your speakers.
Speaker cables not included in the scope of delivery.
Continue with
13
on page 4.
1
2
3
4
5
6
7
8
9
Stereo Mode
Stereo Mode
Stereo Mode
Stereo Mode
Bridge Mode Switch
Speaker Output L
Speaker Output R
AMP CTL
Input L
Input R
Mains Voltage
Mains Switch
Mains Connector
7
9
9
6
8
8
2
3
4