4.2 Breakers
The Super Shred 3 will show a breaker fault by illuminating the Electrical
Fault Light on the main control panel. This light will illuminate if there is
either a breaker trip, or a general wiring fault.
This machine has been configured with 2 different sets of breakers for
operator and machine safety.
These breakers are in the control box in the front of the machine. There are
2 breakers, 1 for the shredder circuit and 1 for the 12 volt start/stop circuit.
Only authorized maintenance specialists or certified electricians must open
and work in this electrical box. The power to the unit must be disconnected
and the machine must be locked out via the disconnect switch on the back
of the machine. The electrical box cover must be removed by loosening the
4 bolts in the corners. When the electrical box is opened, breakers can be
reset/flipped into the ON position. If the breakers are in the ON position
upon opening the control box, a wiring fault must be tracked pinpointed.
Once the breakers have been reset, or the wiring fault observed and fixed,
the electrical box can be closed, power restored, lockout removed, and
operation can resume.