background image

Optional wall mount

1. Position the SPS so that the plug reaches the wall outlet
2. Mark screw holes
3. Unplug the SPS
4. Use 5/16” or 8 mm drill bit to create drill holes
5. Push the supplied 5/16” x 1.5” (8 mm x 38 mm) anchors into the drill holes
6. Secure the SPS into anchors with supplied screws

Disclaimers

This product is intended for indoor use and must be protected from moisture and the elements to maintain
safety, durability, and preserve warranty coverage.

These models are not safety certified. If safety certification is important to you, please visit our store and
select one of our safety certified  Splitter Switch products.

Note that power is prioritized to your dryer, so some special low-power dryer features (such as wrinkle
guard) may interfere with the operation of either your Tesla EV charger or your SPS unit, and therefore is not
supported or recommended. Contact

www.splitvolt.com/help

with any questions or for more information.

This product is designed to operate at a maximum continuous electric vehicle charging rate of 24 amps on a
standard household 30-amp circuit.

According to the National Electrical Code (NEC), exceeding this rate is

unsafe.  It can trip the Splitter Switch internal safety circuit breaker, cutting off power, in order to reduce risk
of damage or risk of fire. Contact an electrician if you ever have questions about local safety codes, or if you
are unsure of the condition of your wiring.

DO NOT DISASSEMBLE. OBSERVE ALL WARNING LABELS. Do not remove warning labels.

Connect to a properly rated, protected, correctly sized power circuit which has been installed to local safety
code standards.

If an electrical supply line, connectors, or other circuit elements are worn or damaged, do not use and
consult a qualified electrician. The Splitvolt Splitter Switch is intended only for use with electrical circuits and
wiring that is in good condition and meets local building safety codes.

6

Splitvolt, Inc.

Summary of Contents for SPS 01-011

Page 1: ...tically with your dryer and EV charger to get Level 2 fast home charging but avoiding the high cost and complexity of having an electrician install a new dedicated 240V charging circuit The Splitter Switch switches full power between your EV charger and clothes dryer automatically provides power for EV charging any time the dryer is not running This new category of product can save you thousands o...

Page 2: ... SPS 02 022 30A 850019012217 NEMA 14 30 NEMA 14 30 NEMA 14 30 SPS 01 031 SPS 01 031 30A 850019012224 NEMA 10 30 NEMA 10 30 NEMA 14 50 SPS 02 032 SPS 02 032 30A 850019012331 NEMA 14 30 NEMA 14 30 NEMA 14 50 NOTE When connecting a NEMA 14 50 EV charger to this device you must restrict the charging rate on either the EV or EV charger to 24 amps When connecting a NEMA 14 50 EV charger to this device y...

Page 3: ...t temperature kWh and status indicators Integrated 25 amp circuit breaker with easy reset for added protection Optional manual power off switch for extra safety and convenience Supports standard 30 amp dryer circuits maximum 24 amp NEC safe charging rate Compatible with common 3rd party electric vehicles and chargers Supports common household dryer 10 30 and 14 30 and charger 10 30 14 30 and 14 50...

Page 4: ...iance dryer Right outlet for EV charger Specifications Wall Plug Pigtail Connector NEMA 10 30 Male for SPS 01 011 NEMA 14 30 Male for SPS 02 022 NEMA 10 30 Male for SPS 01 031 NEMA 14 30 Male for SPS 02 032 Dryer Socket Connector left socket NEMA 10 30 Female for SPS 01 011 NEMA 14 30 Female for SPS 02 022 NEMA 10 30 Female for SPS 01 031 NEMA 14 30 Female for SPS 02 032 EV Socket Connector right ...

Page 5: ...ght 8 4 lbs Limited Warranty 1 Year Standard Safety Certification These models are not safety certified If safety certification is important to you please visit our store and select one of our safety certified Splitter Switch products Quick start 1 Plug the SPS into the 240VAC 30A dryer wall outlet 2 Plug the dryer into the left outlet labeled Dryer of the SPS 3 Plug the EV charger into the right ...

Page 6: ...nded Contact www splitvolt com help with any questions or for more information This product is designed to operate at a maximum continuous electric vehicle charging rate of 24 amps on a standard household 30 amp circuit According to the National Electrical Code NEC exceeding this rate is unsafe It can trip the Splitter Switch internal safety circuit breaker cutting off power in order to reduce ris...

Page 7: ...er Switch devices Troubleshooting The following table identifies steps for troubleshooting the operation of the device If you are experiencing difficulty please review the table below check our website www splitvolt com and then contact us at www splitvolt com help if you are still unable to resolve or have additional questions Issue Resolution Splitter Switch s LED and LCD are not turning on Is p...

Page 8: ... charging NOTE Some special high efficiency sensor dryer settings may cause multiple switching triggering the Tesla charger power protection fault to pause charging It is recommended that Tesla users do not use special low power dryer settings when charging My internal safety breaker keeps tripping off Verify that your EV or EV charger is only charging at 24 amps If it is not set it to charge at o...