Data di emissione:
Dicembre, 2018
Revisione:
1
Pag. :
50/80
“FILTER”
or
“CUT/OUT”
message appears on the
capacitive touch panel
•
The filter is dirty and needs to be
cleaned
•
The unit is positioned too close to a wall
or other object restricting air flow and
causing the machine to run at a higher
temperature
•
The filter is not properly installed
•
The unit has been installed near a heat
source, such as a coffee machine, ice
maker or cold beverage machine which
expels hot air from its vents, causing the
machine to run at a high temperature.
•
Clean and replace filter following
instructions
•
Reposition unit to maximize
ventilation space (see
installation figures)
•
Properly install filter see
•
Reposition unit to maximize
ventilation space (see
installation figures)
Board error code
Possible cause
Solution
E14 or E24 or E34 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
•
The product consistency is too high
•
An ice block is obstructing the auger
rotation
•
Reduce the product consistency
•
Remove ice blocks
E15 or E25 or E35 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
•
An ice block is blocking the auger
rotation
•
The gear motor is defective
•
Remove ice blocks
•
Replace the gear motor
E11 or E21 or E31 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
•
The
temperature
probe
of
the
corresponding bowl is short circuited.
•
Check and replace the probe
E12 or E22 or E32 message
appears on the capacitive
touch panel display.
1, 2 e 3 are respectively the
left, centre and right bowls.
•
The
temperature
probe
of
the
corresponding bowl is disconnected.
•
Check and connect the probe
E01 or E04 or E05 or E06
message appears on the
capacitive
touch
panel
display.
•
The control board is defective
•
Replace the board
E02 message appears on the
capacitive
touch
panel
display.
•
The condenser temperature probe is
short circuited.
•
Check and replace the condenser
probe
E03 message appears on the
capacitive
touch
panel
display.
•
The condenser temperature probe is
disconnected.
•
Check
and
connect
the
condenser probe
Summary of Contents for IPro 1 Slusher ECO
Page 75: ...Data di emissione Dicembre 2018 Revisione 1 Pag 75 80 16 SCHEMA ELETTRICO WIRING DIAGRAM ...
Page 76: ...Data di emissione Dicembre 2018 Revisione 1 Pag 76 80 ...
Page 77: ...Data di emissione Dicembre 2018 Revisione 1 Pag 77 80 ...
Page 78: ...Data di emissione Dicembre 2018 Revisione 1 Pag 78 80 ...