Data di emissione:
January, 2016
Revisione:
1
Pag. :
36/63
SANITIZING
Whenever the machine has remained unused for
some days after been cleaned and sanitized as
described in the chapter 10, the sanitizing
procedures described below must be performed
just prior to start-up the machine.
- Remove the main cover and the secondary
one.
- Pour sanitizing solution (AMUCHINA®) into the
bowl carefully following the manufacturer
prescriptions.
- After restoring the main cover, switch on the
machine and let the auger rotating (all control
board LED switched off) leaving the sanitizing
solution for the time specified by its producer.
IMPORTANT
Never let the sanitizer inside the bowl for
more than 15 minutes.
- Drain the solution by opening the plunger to
allow the bowl to empty. Open and close the
plunger at least 10 times during draining to
sanitize the product way out area also.
- Thoroughly rinse repeating these operations
with clean water instead of sanitizer solution.
- Now the machine is ready to be used.
11. SPECIAL MAINTENTANCE
Caution
Before proceeding with any maintenance
operation, it is compulsory to switch off the
machine and unplug it from the mains.
Condenser filter cleaning
In order to guarantee good cooling system
performance, the condenser filter must be well
cleaned
whenever necessary
.
How to reach it:
- Switch off the power supply and disconnect
the power cable;
- Remove the right and the left panels
remembering to disconnect the earth cable;
- Remove the rear panel remembering to
disconnect the earth cable;
- Remove the dust from the condenser fins by
using a vacuum cleaner;
- Repeat the same operations in reverse order
remembering to connect all the earth cables
back in place.
IMPORTANT
Never use a screwdriver or sharp object to
clean between fins.