background image

INPUT 1

INPUT 2

INPUT 3-10

Disable low voltage cut off by attaching 12/24V from a positive 

power feed.

Activate key-on / lock-out function from a source of 12/24V 

from a positive power feed, such as a fuse or circuit that is live 

when the ignition key is on. WARNING: To avoid a short, always 

attach to input first, power last.

Activate any of the switches (1-8) by an external device that has 

a 3.3 - 24VDC signal.

Use the jumper to switch the 8 inputs between Positive trigger input and 

Ground trigger input. NOTE: this will apply to all 8 inputs.

INPUT FOR SWITCH 8

INPUT FOR SWITCH 7

INPUT FOR SWITCH 6

INPUT FOR SWITCH 5

INPUT FOR SWITCH 4

INPUT FOR SWITCH 3

INPUT FOR SWITCH 2

INPUT FOR SWITCH 1

LOCK-OUT 12/24V POWER INPUT

LOW VOLTAGE CUT OFF BYPASS

INPUT TERMINAL BLOCK

+ / - TRIGGER INPUTS

GROUND TRIGGER: 2 PINS ON THE LEFT

POSITIVE TRIGGER: 2 PINS ON THE RIGHT

INSERT WIRE AND TIGHTEN

USING A MINI

FLATHEAD SCREWDRIVER

WARNING: Always attach to 

input terminal block first before 

attaching to the power side.

10

9
8
7
6
5
4
3
2
1

10

9

8

7

6

5

4

3

2

1

Summary of Contents for BantamX

Page 1: ...R GET TO KNOW YOUR ...

Page 2: ...nputs Ethernet cable 2AMP fuse for circuit board protection Cover Do NOT remove or warranty will be voided Accessories terminal block for switches 1 4 Reverse polarity warning lights lights red if reverse polarity is detected Thumb screw for fastening lid Place holders for switch ID labels legends Auxiliary port identifcations 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 COMPONENTS 1 2 3 4 5 6 7 8 9 10 11 ...

Page 3: ...n lock out control ON position allows switch 2 to only be active when the ignition is on Multiple Source select Used to identify Bantam Multiple Source select Used to identify Bantam DIP SWITCH SETTINGS 1 2 3 4 5 6 OFF ON FACTORY DEFAULT SETTINGS 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1 2 3 4 5 6 ON OFF 1...

Page 4: ... to switch the 8 inputs between Positive trigger input and Ground trigger input NOTE this will apply to all 8 inputs INPUT FOR SWITCH 8 INPUT FOR SWITCH 7 INPUT FOR SWITCH 6 INPUT FOR SWITCH 5 INPUT FOR SWITCH 4 INPUT FOR SWITCH 3 INPUT FOR SWITCH 2 INPUT FOR SWITCH 1 LOCK OUT 12 24V POWER INPUT LOW VOLTAGE CUT OFF BYPASS INPUT TERMINAL BLOCK TRIGGER INPUTS GROUND TRIGGER 2 PINS ON THE LEFT POSITI...

Page 5: ...Open the Bantam app and touch Setup Touch the Scan button and wait 10 seconds Hit Cancel and wait about 10 seconds for the PIN to appear in upper left in white Touch the Setup button Touch the Scan button and wait 10 seconds When Pairing Request dialogue box appears enter PIN number and then touch the Pair button The app will now be paired to the Bantam and will be ready to use To reset pairing wi...

Page 6: ...INSTRUCTIONAL VIDEOS ALSO AVAILABLE ON OUR WEBSITE ...