background image

INSTALLATION

Find a dry, clean, easily accessible, flat surface to mount the SourceLT that 

is within reach of the provided battery cables.

Mount the SourceLT using the provided hardware.

Run control cable through the firewall of the cab. Keep protective cap on 

during the process.

Connect POSITIVE battery cable to the battery & if the vehicle is 2016 or 

newer, chassis ground the sPOD’s negative battery cable. NOTE: This 

should not be done before the previous steps!

Use supplied cable ties to secure all cables.

1

2

3

4

5

LOW VOLTAGE CUTOFF

When the red jumper is set on pins 2 & 3 (the two right pins), the LVCO is 

turned on. This will help protect your battery from draining due to accessories 

being left on for too long. (See Figure A.) When enabled, the system will shut 

down when the voltage drops below 11.6 volts after a 2-minute period. 

When the red jumper is set on pins 1 & 2 (the two left pins), the LVCO is turned 

off. This will not protect your battery from draining due to accessories being 

left on for too long. (See Figure B.)

ENABLED

DISABLED

LVCO JUMPER LOCATION

FIGURE B. LVCO DISABLED

FIGURE A. LVCO ENABLED

1    2     3

1    2    3

Summary of Contents for SourceLT

Page 1: ...R GET TO KNOW ...

Page 2: ...P switch for pairing Bluetooth see page 3 Jumper for low voltage bypass see page 2 Controller input 2AMP fuse for harness circuit board protection Accessories terminal block for switches 1 3 Thumb screw for fastening lid Place holders for switch ID labels legends 1 2 3 4 5 6 7 8 9 10 COMPONENTS 1 2 3 4 5 6 7 8 9 10 ...

Page 3: ...teps Use supplied cable ties to secure all cables 1 2 3 4 5 LOW VOLTAGE CUTOFF When the red jumper is set on pins 2 3 the two right pins the LVCO is turned on This will help protect your battery from draining due to accessories being left on for too long See Figure A When enabled the system will shut down when the voltage drops below 11 6 volts after a 2 minute period When the red jumper is set on...

Page 4: ...app and touch Setup Touch the Scan button and wait 10 seconds Hit Cancel and wait about 10 seconds for the PIN to appear in upper left in white Touch the Setup button Touch the Scan button and wait 10 seconds When Pairing Request dialogue box appears enter PIN number and then touch the Pair button The app will now be paired to the SourceLT and will be ready to use To reset pairing with all devices...

Page 5: ...ling fault protection system from 1 5 to 30amps Current sensing MOSFETs controlled by a microprocessor no fuses no relays 50amp auto resetting circuit breaker Nylon braided battery cables are hi strand crosslinked copper wire with a silicone jacket Operates on 12VDC Built in Bluetooth capabilities for remote control Protection against overheating over current shorts reverse polarity and field coll...

Page 6: ...INSTRUCTIONAL VIDEOS ALSO AVAILABLE ON OUR WEBSITE ...

Reviews: