Troubleshooting
Model no.: G575R
Malfunction item: ERROR_1_6
Circumstance: Display showing “ERROR_1_6” when power on
Possible causes: 1.Product voltage setting incorrect
Troubleshooting: 1.Press & hold “workout level<▲> & <▼> & <change display>
for 3 seconds to enter voltage setting
2. Set the voltage on MI drive board for 110V or 220V for those
products produced before May 2014
3. This problem only occurs on first installation or repair MI
drive board
3-7-1
MI drive board
220V
110V
Press & hold “workout level<▲> & <▼> & <display
change> to set model no. and AC VOLTAGE