10.7.
ECG is not connected to the treadmill
Please check that Runner RS232 cable is used to connect the treadmill to ECG.
Don’t use any other RS232 cable.
Please check if the right communication protocol has been set up (
see 5.11.5 Input protocol
).
If serial adaptor USB-RS232 is used, please check the right functioning.
10.8.
The running belt stops and restarts
Control the belt tension (see 3.11 best running belt tension) because if belt is too loose or too much lubricated
it could slip.
10.9.
Running belt doesn’t go on
Set up the speed and push start key on the console touch screen. Check if the inverter display is on, if it shows
numbers (they refer to set up speed) and the red led “RUN” is on.
10.10.
The running belt doesn’t keep center
The belt is too tight or user hangs on only one side handle. (See 3.10 how to center the running belt)
10.11.
Inclination doesn’t work
Check the fuse (
8AT, 250V
for range RUN7410/T
–
range RUN7411/T or
5AT, 250V
for range
RUN2011/T
) inside fuse box near the machine power switch. If it’s o.k. contact the
manufacturer (See chapter
1 recapitulation machine marking data). If it’s off
replaced it.
Check in the power board RUN1801 if two green led are on fixed and one blinking. Besides check in PC board
if seven green led plus one yellow led are on and one yellow led is blinking.
If all checks are positive, contact Runner Srl.