Troubleshooting
Model No.: E875
Malfunction item: No power - generator
Circumstance: Display not lit up when power on
Possible causes: 1.wiring connections
2.Generator fuse burnt
3.Bad drive board
4.Bad control board
Troubleshooting: 1.Check generator fuse
2.Check all wire connections
3.Pedaling & check drive board LED1,LED2 indicators
Or replace drive board
4.Check program board on the control board
3-1-1
Drive
Board
Display
board
Alternator
發電機保險絲 2A
LED13
LED15
LED1 12V(control
board)
LED2 Vcc
F2 generator fuse
Power
indicator
Summary of Contents for E875
Page 1: ...E875 Repair manual Electronics...
Page 2: ...1 1 Product E875 1 1 1...
Page 3: ...1 2 Display E875 1 2 1...
Page 4: ...1 3 Component placement E875 Display 1 3 1 Control board Program board...
Page 8: ...1 5 Wiring diagram E875 1 5 1...
Page 13: ...1 6 LED indicator E875 Display 1 6 1 POWER1 LED2communication indicator...