Troubleshooting
Model
E875
Malfunction item: No power – rechargeable battery
Circumstance: Display not lit up when power on
Possible causes: 1.Wiring connections
2. Rechargeable battery wiring
Troubleshooting: 1.Check drive board battery fuse
2. Measure battery voltage and it should be
above 12V/one battery; therefore 24V for 2
3.Check drive board LED1, LED2 indicator
4.Use battery charger to charge it if the
voltage is too low
3-1-2
Drive
Board
Display
board
Battery
Fuse
LED2 VCC
LED1 12V
F2 battery charging fuse
蓄電池
12V *2
F3 battery Fuse
Battery Fuse