Troubleshooting
Model: T611
Malfunction: Safety key malfunction
Circumstance: Put the safety key in place. The display shows no reaction.
“Safety key” appears.
Possible cause: Safety key board malfunction
Troubleshooting: 1. Inspect the safety key magnet.
2. Inspect bridge board connections.
3. Test or replace the safety key board.
3-1-1
Display
Board
Bridge
board
Safety key
board
Safety key board
Safety key cable
Safety key reed switch test
Put safety key
magnet in place
Reed switch: electrical
continuity
ON
Do not put the
safety key magnet
in place
Reed switch: electrical
open
OFF
Summary of Contents for T611
Page 1: ...T611 Repair Manual Electronics...
Page 4: ...1 1 Product Picture T611 1 1 1...
Page 5: ...1 2 Overlay T611 1 2 1...
Page 7: ...1 3 Connections T611 Bridge Board 1 3 2 To Safety key board HTR board Soft key Bridge board...
Page 11: ...1 5 Connections T611 Bridge Board 1 5 2 To Safetykey board To HTR board To Display...