Troubleshooting
Model: T611
Malfunction: HTR malfunction
Circumstance: Contact heart rate (HTR) value
malfunction
Possible cause: 1. HTR cable malfunction
2. HTR board malfunction
3. Display cable connection malfunction
Troubleshooting: 1. Inspect the display cable
connections.
2. Inspect bridge board HTR cable connections.
3. Inspect contact heart rate cable connections.
4. Inspect HTR board LEDs.
5. Replace the HTR board.