Troubleshooting
Model:
T615
Malfunction: Incline will not operate upward or downward.
Circumstance: Press incline keys; there is no incline action.
Possible causes: 1. Incline VR or drive board has malfunctioned.
2. Cables are not connected well.
3. Incline motor is not operating.
Troubleshooting: 1. Inspect drive board cable connections.
2. Inspect transformer voltage.
3
. Inspect incline signal indicators on the drive board
and measure incline output voltage.
4.
. Listen for the sound of incline gear grinding.
the drive board could be malfunctioning.
5.
Replace the drive board.
3-5-1
Incline UP/DOWN led
Transformer(orange-orange 29V)
Display Board
Drive Board
Incline
Motor
VR
SET
Transformer
Incline VR