Troubleshooting
Model: T621
Malfunction: Unit does not operate
Circumstance: Turn on unit power; the power indicator does not light.
Possible cause: Inadequate incoming power supply or component malfunction.
Troubleshooting: 1. Inspect the power cable connection.
2. Inspect cable connections under the motor cover.
3. Inspect the main fuse, fuse holder, and the power switch.
4. Inspect drive board components for signs of burning. Or replace the drive board as a test.