Troubleshooting
Model: T621
Malfunction: Contact (Heart Touch Rate) malfunction
Circumstance: Place hands on heart rate contact
sensors. Heart rate values appear to be
inaccurate.
Possible causes: 1.HTR cable connection
2. HTR board malfunction
3. Display cable connections
Troubleshooting: 1. Inspect the display cable connections.
2. Inspect bridge board HTR cable connections.
3. Inspect contact heart rate cable connections.
4. Inspect the HTR board indicator LEDs.
5. Replace the HTR board.
3-5-1
Bridge board
Display
board
HTR board
Sens
or
-L
Sens
or
-R
HTR Indicators
LED
Name
Function
LED1
POLAR LED
Flashing indicates incoming
telemetry signal.
LED2
HTR contact LED
Lit indicates user is gripping HTR
contact.
LED3
HTR signal LED
Flashing indicates incoming HTR
signal.
LED4
HR output
Each flash indicates a pulse signal
output.
HTR contact plate (clean here)
HTR
HTR cable
HTR
HTR connector