XT20 Error Messages: Unit does not start when keys are pressed.
1. Explanation:
1. Press <START> or <Quick START> keys on the display. The display does not light.
2. Block diagram:
控制板
驅動板
蓄電池
CA
BL
E
開機電壓
Keypad
按START
或QUI CK START
保險絲F2
Start
Quick Start
Display Board
o
Power LED
Fuse F2
Drive Board
Battery
Voltage
Keypad
6-1-1
POWER
◎
Summary of Contents for XT20 Cross Trainer
Page 1: ...XT20 Cross Trainer Repair Manual SPORTSART INDUSTRIAL CO LTD...
Page 5: ...XT20 Picture 1 1 1...
Page 6: ...XT20 Display 1 2 1...
Page 8: ...XT20 Lower Body Front 1 3 2 AC alternator Flywheel Electro magnet Battery Reed switch...
Page 9: ...XT20 Display 1 4 1...
Page 10: ...XT20 Display Board Front 1 5 1...
Page 11: ...XT20 Display Board Back 1 5 2...
Page 31: ...XT20 Display Board Component Placement 5 1 2...
Page 35: ...XT20 Drive Board Component Placement 5 2 2...
Page 53: ...XT20 Alternator Test 1 Alternator test configuration 7 1 1...
Page 59: ...XT20 Alternator Power Test at the Drive Board 1 Test Configuration 7 5 1...
Page 61: ...XT20 Battery Test at the Drive Board 1 Test Configuration 7 6 1...
Page 64: ...Test Configuration LEG Resistance Voltage Test 7 7 2...
Page 66: ...XT20 VCC Voltage Test at the Drive Board 1 Test Configuration Normal reading 5 VDC 7 8 1...
Page 68: ...XT20 VCC Voltage Test at the Display Board 1 Test Configuration 7 9 1 Capacitor C10...