XT20 Error Message: There is no resistance on arms or legs.
1. Explanation:
1. The reed switch CLK signal does not reach the display CPU. The unit does not start.
There
is no resistance.
2. The display has not sent the resistance signal to the drive board. The drive board has not sent voltage
to the electro-magnet, so there is no resistance.
2. Block Diagram:
控制板
驅動板
阻
力
訊
號
電磁鐵
CA
BL
E
阻力電壓
磁簧感應線
CLK
發電機
AC電壓
V
Display
Board
Electro-
Magnet
Reed
Switch
Alternator
Drive
Board
Resistance
Voltage
AC
Voltag
e
CLK
Resistance
Signal
6-4-1
Summary of Contents for XT20 Cross Trainer
Page 1: ...XT20 Cross Trainer Repair Manual SPORTSART INDUSTRIAL CO LTD...
Page 5: ...XT20 Picture 1 1 1...
Page 6: ...XT20 Display 1 2 1...
Page 8: ...XT20 Lower Body Front 1 3 2 AC alternator Flywheel Electro magnet Battery Reed switch...
Page 9: ...XT20 Display 1 4 1...
Page 10: ...XT20 Display Board Front 1 5 1...
Page 11: ...XT20 Display Board Back 1 5 2...
Page 31: ...XT20 Display Board Component Placement 5 1 2...
Page 35: ...XT20 Drive Board Component Placement 5 2 2...
Page 53: ...XT20 Alternator Test 1 Alternator test configuration 7 1 1...
Page 59: ...XT20 Alternator Power Test at the Drive Board 1 Test Configuration 7 5 1...
Page 61: ...XT20 Battery Test at the Drive Board 1 Test Configuration 7 6 1...
Page 64: ...Test Configuration LEG Resistance Voltage Test 7 7 2...
Page 66: ...XT20 VCC Voltage Test at the Drive Board 1 Test Configuration Normal reading 5 VDC 7 8 1...
Page 68: ...XT20 VCC Voltage Test at the Display Board 1 Test Configuration 7 9 1 Capacitor C10...