DOM 1000 - DOM 1000 A

DOM 1000 - DOM 1000 A

5

ELECTRICAL CONNECTIONS

The luminaire is designed to operate with a 100V to 
240V supply, 50-60Hz, according to the lamp used.

Before and during the installation, make sure you follow 
the guidelines below:
• Always check the earth wiring for the line being used.
• Verify that the lamp voltage is correct for the main 

voltage

• Do not use lamps other than indicated on the lamp 

table

• There are no fuses inside the units, if it is necessary  

they should be installed in the mains

• The luminaires can be connected to a dimmer

INSERTING AND CHANGING THE LAMP

- To remove the safety net, insert a screwdriver into the 

access point 

⑥ 

and push upwards

- Open the safety net
- Replace the lamp without touching the glass bulb
- Fix the safety net by pushing its frame 

 forwards/

down into the locking guide.

Please note that when changing the lamp,  the position 
of the projector must not necessarily be changed so 
that the focus of the projector  can stay still.

DESCRIPTION OF THE LUMINAIRE

Referring to images on page 2:

① 

  Suspension yoke

  Rear handle

  Positioning spring

 

  Filter-holder

  Safety net

⑥ 

Access point for safety net opening

  Point for safety net closing and locking

INTRODUCTION

The luminaire you have bought conforms to 73/23/EEC, 
93/68/EEC,  EN 60598-1 and EN 60598-2-17 directives 
and regulations.
The label on the side of the luminaire lists the following 
information:
• model
• mains supply voltage (V)
• lamp wattage (W)
• IP protection index
• maximum allowed ambient temperature in °C
• maximum temperature of the body in °C 
• minimum distance from flammable surface
• information to find the position 0° of the luminaire: 

when the tip of the arrow points upwards 

• maximum tilt angle range. These limits, imposed by 

the lamp manufacturer, should not be exceeded as 
they would reduce the luminaire’s useful life or lead 
to its deterioration.

INSTALLATION

• The luminaires are intended for professional use only 

so they have to be installed and used by qualified 
technicians.

• The products are intended for indoor use: 

consequently they have to be protected from humidity 
and rain, if used in different conditions (IP 20)

• Do not mount the luminaire on or near a flammable 

surface

• Please note carefully the notes written on the labels 

of the luminaires.

• Do not forget to connect a safety rope, if required by 

local country safety regulations

• For safety requirements the net shall be mounted 

on the front of the lamp to prevent any large glass 
fragments from falling in case of breaking.

• The projector can be either suspended or placed on a 

plane surface.

WARNING: replace immediately the 
lamp if visibly damaged, even if still 

working.

WARNING: The luminaires must always be 
earthed

WARNING: For safety reasons always discon-
nect the projector from the mains before 

opening it to change the lamp.

www.liveline.be

Summary of Contents for DOMINO DOM 1000

Page 1: ...Manuale utente User manual cod DOM 1000 DOM 1000 A Domino www liveline be ...

Page 2: ...on potrà essere ritenuta responsabile di danni derivanti dalla non osservanza di dette istruzioni SAFETY WARNING Before using this product read the present instructions carefully Spotlight srl will not be responsible for damage resulting from instructions not being followed 3 2 1 Kg 3 9 Dimensioni mm e peso Dimensions mm and weight www liveline be ...

Page 3: ... CEE e 93 68 CEE in quanto conforme alle norme EN 60598 1 ed EN 60598 2 17 La targhetta che è localizzata sul lato posteriore del faro contiene le seguenti informazioni modello massima tensione di alimentazione in V massima potenza della lampada in W indice di protezione IP massima temperatura ambiente ammissibile in C massima temperatura del corpo del faro in C distanza minima da ogni superficie ...

Page 4: ...rete di protezione ed il diffusore Per far questo dopo aver scollegato il faro dalla rete di alimentazione si può aprirlo per pulire con uno straccio soffice inumidito con alcool sia la rete di protezione che lo specchio MANUTENZIONE Sottoporre il faro a revisione almeno una volta all anno per controllare l integrità delle parti elettriche e meccaniche A tal fine utilizzare solo rivenditori qualif...

Page 5: ...lations The label on the side of the luminaire lists the following information model mains supply voltage V lamp wattage W IP protection index maximum allowed ambient temperature in C maximum temperature of the body in C minimum distance from flammable surface information to find the position 0 of the luminaire when the tip of the arrow points upwards maximum tilt angle range These limits imposed ...

Page 6: ...d the reflector must be kept as clean as possible To do so after disconnecting the projector from the mains both the safety net and reflector can be cleaned with a soft cloth dampened with alcohol MAINTENANCE At least once a year the luminaire should be serviced to ensure the integrity of the electrical and mechanical components For this purpose please address only to qualified dealer to ensure pr...

Page 7: ... Barra per quattro Domino in linea 4x1 Bar for four Domino in line D 4x1 Colour Scroller Cambiacolori a nastro motorizzato con controllo DMX Colour Scroller Motorised scrolling colour changer DMX controlled a richiesta on request Lampade Lamps Modello Model Type Code V W lm K t h DOM 1000 P2 10 230 625 R7s 15600 3200 150 K3 230 750 R7s 15500 3050 1500 P2 7 230 1000 R7s 26000 3200 200 K4 230 1000 R...

Page 8: ...Via Sardegna 3 20098 S Giuliano Milanese Milano Italy Tel 39 02 98830 1 Fax 39 02 98830 22 E mai info spotlight it www spotlight it certified quality management system ISO 9001 2008 DOM 1000 DOM 1000 A www liveline be ...

Reviews: