25
TJM60AG
Tank Cleaner ǀ 08/07/2017
TROUBLE SHOOTING GUIDE
The following is a table indicating various potential modes of failure for this product.
Mode of Failure
Description
Preventative or Corrective Actions
Maximum pressure and
temperature ratings
Maximum fluid pressure for the TJM60AG
is 1,000 PSI (70 BAR)
Do not exceed maximum fluid
pressure rating.
Maximum fluid temperature for the
TJM60AG is 180°F (82°C)
Do not exceed maximum temperature
pressure rating.
Maximum air pressure for
air motor is 20 psi
Do not exceed maximum air pressure
rating. Use suggested air pressure range
of 10 psi to 20 psi to operate TJM60AG
tank cleaner .
Minimum and maximum ambient
temperature the TJM60AG tank cleaner
can be exposed to is+35°F to +125°F
(+2°C to +52°C)
Do not operate TJM60AG tank cleaner
outside the acceptable ambient
temperature range.
Worn nozzle hub seals
Excessive fluid leakage in nozzle hub
Replace worn nozzle hub seals with
new seals . See maintenance section for
instructions on how to replace seals
Worn gear box seals
Excessive fluid leakage in gear box
Replace gear box seals with new seals.
See maintenance section for instructions
on how to replace seals .
Nozzle head on
TJM60AG tank cleaner
does not rotate and
shear pin is broken
Check to see if shear pin that is located
on drive shaft that engages with coupling
near motor is broken
If shear pin is broken could be the result
of excessive seal leakage causing an
overload condition . If seals are worn
replace seals and then replace shear pin .
If shear pin still breaks could be the result
of an excessive load from worn bevel gears
in gear box. Tank cleaner should be sent
back to Spraying Systems Company for
repairs .