background image

 

 

   |    / /

 

MOUNTING: 

The PulsaJet® 10000AUH-03-Z1 can be mounted in any orientation using the 

threaded holes to mount to a bracket or other surface. Alternately, it may be 

supported by the inlet piping if rigid pipe is used. Mounting holes, inlet 

connections and outer dimensions are shown on Figure 2. 

 

 

 

 

 

FIGURE 2 – OVERALL 

DIMENSION OF 

AA10000AUH-03-Z1 

 

Summary of Contents for PulsaJet 10000AUH-03-Z1

Page 1: ...PulsaJet 10000AUH 03 Z1 USER GUIDE spray com MI 10000AUH 03 Z1 for NPT BSPT Models...

Page 2: ...ned tasks US installations shall comply with the relevant requirements of the National Electrical Code ANSI NFPA 70 European installations shall comply with the relevant requirements of EN 60079 14 Ma...

Page 3: ...temperature and chemical resistance SPECIFICATIONS Power Requirements 27VDC Max 0 30 AMPS Max Inlet connections 1 8 NPT for AA10000AUH 03 Z11 8 BSPT for AAB10000AUH 03 Z1 Electrical conduit connectio...

Page 4: ...uld be plugged using 1 8 pipe plug which is provided with each unit ELECTRICAL CONNECTIONS Electrical conduit connection for conduit fitting accepts 1 2 NPT M for NPT version The conduit must protect...

Page 5: ...5 FIGURE 1 ELECTRICAL SCHEMATICS FOR AA10000AUH 03 Z1 AutoJet 24VDC based controller or other appropriate solenoid driver...

Page 6: ...ation using the threaded holes to mount to a bracket or other surface Alternately it may be supported by the inlet piping if rigid pipe is used Mounting holes inlet connections and outer dimensions ar...

Page 7: ...ch it is used FLUID SUPPLY Make sure maximum pressure rating of 100 psi 7 bar is not exceeded To help prevent clogging problems the fluid supply line needs to include a line strainer MAINTENANCE All p...

Page 8: ...spray tip Remove spray tip and clean orifice or replace tip Debris in fluid passages Disassemble nozzle and clean fluid passages Plunger not operational Check coil for nominal resistance of 67 Ohms If...

Page 9: ...r to the Parts List for an exploded view and identification of numbered items FIGURE 3 AA10000AUH 03 Z1 EXPLODED VIEW Item Part No Description 1 CP1325 SS Retaining Cap Stainless Steel Type 303 2 AB10...

Page 10: ...10 RATINGS AND LABEL INFORMATION FIGURE 4A PULSAJET AA10000AUH 03 Z1 SPRAY NOZZLE LABEL NPT VERSION FIGURE 4B PULSAJET AAB10000AUH 03 Z1 SPRAY NOZZLE LABEL BSPT VERSION...

Page 11: ...EN 60079 18 FM10ATEX0040X1 The Electromagnetic Compatibility Directive 2014 30 EU of 26 February 2014 EN 61000 6 4 EN 61000 6 2 N A As per Article 14 and Annex II and III of 2014 30 EU a technical co...

Page 12: ...Avenue and Schmale Road P O Box 7900 Wheaton IL 60187 7901 Tel 1 800 95 SPRAY Intl Tel 1 630 665 5000 Fax 1 888 95 SPRAY Intl Fax 1 630 260 0842 www spray com MI 10000AUH 03 Z1 rev 3 Spraying Systems...