7
OPERATION
CHEMICAL COMPATIBILITY:
Be sure the fluids used in the AA(B)10000AUH-03-Z1 are compatible with and will
not cause deterioration of the materials of construction shown in the introduction
to this document.
SAFETY:
•
To prevent possible ignition, do not disconnect while energized.
•
Make sure all equipment is rated and approved for the environment in which
it is used.
FLUID SUPPLY:
•
Make sure maximum pressure rating of 100 psi (7 bar) is not exceeded.
•
To help prevent clogging problems, the fluid supply line needs to include a
line strainer.
MAINTENANCE
•
All power to the PulsaJet® nozzle must be turned off before any
maintenance is performed on the unit.
•
Overspray or other material should not be allowed to build up on the outside
of the PulsaJet nozzle.
•
If clogging occurs, the valve components can be removed from the front by
first removing the spray tip and then unscrewing the seat. See Rebuild
Instructions below.