24
• Do not re-enter the property until the alarm has
stopped When exposed to fresh air it can take up to 10
minutes for the sensor to clear and the alarm to stop
depending on the level of carbon monoxide detected
• Get medical help immediately for anyone suffering
the effects of carbon monoxide poisoning (headache,
nausea), and advise that carbon monoxide poisoning
is suspected
• Do not use the appliances again until they have been
checked by an expert In the case of gas appliances the
engineer must be registered on the Gas Safe register
TECHNICAL INFORMATION
Detector Specifications:
Model CO-9X
Sensor Type:
Electrochemical
Sensor Life:
7 Years
Alarm Sound Level:
85dB at 1 metre (3 feet)
Power Pack Life:
7 years (Life of product)
Temperature Range:
-10ºC (14ºF) to 40ºC (104ºF)
Operating Humidity Range: 30 - 90% RH
Weight:
90 grams (3 2oz)
Certified to:
EN 50291-1:2010+A1:2012,
EN 50291-2: 2010
This FireAngel carbon monoxide detector is designed
to continuously monitor for CO Its response times
meet the requirements of the European standard
EN 50291-1: 2010+A1:2012 and EN 50291-2: 2010