8
WCB_D4_D4SL_sch5_US.indd
D4 / D4 SL Schedule 5 Series
Double Seat Mix Proof Valves
Instruction Manual: US - rev. 0
Waukesha Cherry-Burrell
®
brand D4 / D4 SL Schedule 5 Valves
5. Control Units / Valve Position Indication
5.1.
Control unit and adapter
An adapter is required to assemble the control unit on the D4/D4 SL
valve. The following different designs are available:
Designation
D4
D4 SL
Ø Air connection
1/4" OD
1/4" OD
CU4 Control Unit
Direct Connect
CU41-D4
Direct Connect
H336959
CU43-D4
Direct Connect
H336960
AS-interface
extended
CU41-D4
AS-i extended
H336961
CU43-D4
AS-i extended
H336962
AS-interface extended M12
CU41-D4-M12
AS-i extended M12
H338900
CU43-D4-M12
AS-i extended M12
H338901
AS-interface standard
CU41-D4
AS-i standard
H338151
CU43-D4
AS-i standard
H338153
AS-interface
standard M12
CU41-D4-M12
AS-i standard M12
H338902
CU43-D4-M12
AS-i standard M12
H338903
Adapter
CU4 adapter D4
H337098
CU4plus Control Unit
AS-interface
extended V1
CU41plus-D4-V1
AS-i extended V1
H338823
CU43plus-D4-V1
AS-i extended V1
H338824
AS-interface extended V1
M12
CU41plus-D4-V1-M12
AS-i extended V1 M12
H338868
CU43plus-D4-V1-M12
AS-i extended V1 M12
H338869
Adapter
CU4plus adapter D4 V1
H336441
CU4 control unit
5.2.
Valve position indication
Proximity switches to signal the closed and open position of the valve
can be installed at the proximity switch holder.
We recommend using one of these standard types:
three-wire proximity switch
operating distance: 0.196" (5 mm)
diameter:
0.433" (11 mm)
operating voltage: 10–30 V DC
pnp pulse-shifting, closing function
"non-flush" installation
Recommendation:
Proximity switch 24V DC, PNP, 11 mm DIA. (5 m cable): H16223
Proximity switch 24V DC, PNP, 11 mm DIA. (cable box): H16432
Note: If the customer decides to
use valve position indicators other
than those listed, SPX FLOW can-
not assume any liability for the
functionality of the valve.