Square Scrub Limited Warranty
This Square Scrub product is warranted to be free from defects in materials and workmanship
under normal use and service for a period of one year from the date of purchase, when operated
and maintained in accordance with Square Scrub Maintenance and Operating Instructions. Damage
due to misuse or improper care will not be repaired under warranty.
This warranty is extended only to the original purchaser for use of the product. It does not cover
normal wear and tear parts such as electrical cable, rubber parts, pad driver, main bearing and
motor brushes.
Note: The rubber isolators are considered wearable parts. It is recommended that the entire set
of four (or eight on EBG-28) isolators be replaced every year, regardless of the number of hours
operated.
If a difficulty develops with the product, contact your local Square Scrub dealer or call Square
Scrub at 800.557.6822. Only Square Scrub can authorize repairs under warranty.
Transportation charges to and from the repair location, including motors still under warranty, will
be paid or prepaid by the purchaser. Freight charges on parts are not included. The purchaser will
bear full financial responsibility for any freight, testing and assembly if the warrantied Square
Scrub or motor is found to be defect-free.
Square Scrub’s liability under this warranty is limited to repair of the product and/or replace
-
ment of parts and is given to purchaser is lieu of all other remedies, including INCIDENTAL AND
CONSEQUENTIAL DAMAGES.
THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE SPECIFIED HEREIN.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE
HEREOF. NO
WARRANTIES, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY,
SHALL BE IMPLIED.
Please register your machine on our website within thirty (30) days of purchase to assist Square
Scrub in providing the performance you expect from your new floor machine.
Square Scrub
800-557-6822
www.squarescrub.com
Machine Serial #:_____________________
Date of Purchase:_____________________
page14
page 13
Problem
Cause
Action
Machine will not start
Not Connected to power source
Voltage too low
Defective switch
Check power source connection and
lighted plug
Have electrician check outlet
Contact Square Scrub dealer
Runs erratically
Low voltage from excessive
length or undersized
extension cord
Defective start switch
Defective motor low voltage
Use 10 gauge extension cord
Not more than 25’ long
Contact Square Scrub dealer
Contact Square Scrub dealer
Fuse/Circuit Breaker Trips
Low voltage
Low input volts
Allow the motor to cool. The circuit
breaker is a red button on the side of
the motor that will reset when pressed.
Eliminate extension cord.
Locate power cord closer to work site.
Have voltage checked by
electrician.
Machine pulls hard to one side
Note:
The rubber isolators on the EBG are
considered wear items. It is recommended to
replace the entire set of all four isolators once
per year (or sooner under heavy use) to prevent
failure and damage to the machine.
Worn Pad
Rubber isolators are worn out
Rotate pad 180 degrees
Flip pad over
Replace Pad
Replace isolators
Machine is noticeably louder than
it was when originally purchased
Rubber isolators worn
Removable weights not secured
Replace isolators
Tighten knobs on removable weights
Troubleshooting