( 7 / 12)
Now please click by right button of mouse inside DMX window. Next dialog will be
displayed
DMX:
is DMX channel which trigger the command
Low / High value:
1-512 – command will be sent when there is DMX value of 1-521
128-512 : command will be sent when DMX value is greater than 50%
RS232 command:
This will be sent out from RS232/RS422 – use maximum of 19
characters
Function name:
Here you can write something about command to know what was
programmed. Use maximum of 19 characters.
Please click to FILE>SAVE. Now you can see two commands that are programmed.