02-18
korando 2010.10
0000-00
AIR BAG SYSTEM
When there is an active fault or past faults occurred 10 times or more
▶
If active fault or past faults which occurred 10 times or more in the last ignition cycle, the SDM
operates the warning lamp as shown below. If below conditions are met, the SDM is operated
in the same way.
Active fault
When the past faults occurred 10 times or more (except 'battery voltage too low')
Internal fault
Impact record
Pretensioner fired only
-
-
-
-
-
If the connector is not connected properly or SDM battery voltage is out of the specified range
internally (battery voltage for warning lamp), the warning lamp is kept ON.
Warning lamp condition change during operation
▶
The warning lamp comes on or off according to the actual fault condition during SDM operation.
If there is any active fault or active fault becomes past fault, the warning lamp is illuminated,
and if the fault is deactivated, the warning lamp is turned off.