background image

Assembly/operating instructions for SSC-LUXon motion detector KELEA 990070794 / 990070795

1. Intended use 

 

 

 

 

 

 

 

 

 

 

 

 

 

              

This product: -can be installed indoors and outdoors -protection type IP54, suitable for use in damp areas -must not be exposed to strong mechanical loads or heavy soiling 

-may not be operated after damp or dirty storage until after a condition check -may not be changed or modified, otherwise the operating permit and conformity will expire 

with immediate effect!

It is not allowed to remove the type plate.

 If the aforementioned points are not observed, a short circuit or electric shock may occur! 

There is danger to life!

   

             

2. General safety instructions 

 

 

 

 

 

 

 

 

 

 

 

 

              

 The complete installation may only be carried out by an authorized electrician who is familiar with the applicable guidelines. Hereinafter referred to as „qualified 

 

electrician“.

 For safe handling of the product, the user must have read and understood the installation/operating instructions completely before using the device for the first time.

 The product may only be used if it is alright. If the device or parts of it are defective, it must be repaired by a qualified electrician.

 This product is not a toy and is not allowed be stored or used within the reach of children.

 Safe operation of the product is only guaranteed if these instructions are followed. Therefore, keep these assembly/operating instructions. SSC-LUXon GmbH accepts no 

liability if the instructions given here are not followed or the lamp is subjected to improper use.

3. Assembly & configuration

   

 

 

 

 

 

 

 

 

 

 

                                 

 

Caution: 

The connecting cable must be disconnected from the power supply before starting work (switch off the main switch/fuse)! Only use parts which are supplied with 

the product or which are clearly marked as equipment! Otherwise the product may not be sufficiently safe!

 

The cable routing shown in the illustrations is for simplified purposes only. They in no way represent a recommendation for connection! The connection may only be 

carried out by a qualified electrician. 

 

When drilling, pay attention to cables and gas and water lines.

3.1 Assembly location

The product is suitable for mounting indoors & outdoors. Do not cover the product under any circumstances, especially not with insulating material!

4. Operation, faults & disorders 

 

 

 

 

 

 

 

 

 

 

 

               

 

Caution:

 Disconnect the connection cable from the power supply before starting work! 

What to do in case of error?

In case of an error, the device must be switched off immediately. The product may only be operated if it works correctly. The device may only be put back into operation after 

it has been checked by a qualified electrician!

 This is the case if:

1. there is visible damage, 2. the product is not working corrctly, 3. there is smoke, steam, or audible crackling noises, 4. overheating can be detected. 

 

Caution: 

There is a danger to life - repairs to the product or work on parts carrying mains voltage may only be carried out by qualified electricians.

 

Avoidance of disturbances and fire hazards:

It is not allowed to cover the product under any circumstances. Air circulation must be ensured. Nothing may be attached or hung on the product, especially no decoration.

5. Cleaning & care instructions 

 

 

 

 

 

 

 

 

 

 

 

 

              

The product may only be wiped dry or carefully with a slightly damp and lint-free cloth. The product is not allowed to be removed for this purpose. Do not use abrasive or 

sharp objects or aggressive cleaning agents. Do not use solvents.

Assembly instructions KELEA motion detector 990070794 / 990070795 

 

 

                                                

    

 

            

 

1. Disconnect the connecting cable from the power supply!

2. Loosen the cover on the back. Use as large a slotted screwdriver as possible. Lever out the cover by placing the screwdriver in the recess and 

carefully turning it. 

Fig.1

3. Drill through the marked spots on the cover (Ø 2 - 3 mm drill bit). Depending on where you want to install the motion detector: Wall or ceiling 

mounting / on 90° corners / in 90° corners. 

corners. 

Fig.2

 

 

Tip: 

Hold the cover against the light to see the markings better.

 

4. Mark the drill holes with the help of the back plate and drill the holes. Insert the the dowels into the holes. Feed the connection cables through the 

round rubber seals (pierce 2 cables each).

5. Screw the back plate to the wall. Connect the connection cables (input) to the luster terminal with the designation N & L (blue & black). Connect the 

connection cables (output) to the luster terminal with the designation A & N (red & blue). 

Fig.3

 

 

 

Note: 

Input = current-carrying cable (supply cable) / Output = cable to the consumers (e.g. lights etc.). The designations A, N & L are also printed 

on the luster terminal.

6. Adjust the sensitivity and the light duration with the knobs on the bottom. 

Fig.4

  

7. Plug the motion detector onto the mounted cover. Make sure that the connection is firmly seated (latching sound).

8. Switch the connecting cable to voltage. The product is now ready for use.

Model:

 

   990070794 

990070795

Type:

 

 

 

 

KELEA motion detector PIR swivelling & adjustable

Voltage:

 

 

 

 

20-240 V AC - 50/60 Hz

Protection type:

 

  IP54

Max. angle of coverage:   

 

180° + 360°

Material:

 

   Plastic

Operating temperature:

   

 

-20° C - +40° C

Max. detection range:

   

 

12 meter

Protection class:

 

  II

Lighting duration: 

 

 

10 sec. to 15 min.

Can be used 

indoors and 

outdoors

Installation height wall / ceiling:

 

 

1,8-2,5 m / 2,2-4 m

Max. power consumption:

 

 

2000 W

Colour:

 

   White 

black

Technical data KELEA motion detector 990070794 / 990070795    

 

 

 

                                           

 

 

 

                

SSC-LUXon GmbH – Am Krozinger Weg 4, 79189 Bad Krozingen, Germany 
E-Mail: service@ssc-luxon.de; Phone: +49 7633 - 988 3000

1. 

Turn the time knob anticlockwise at the minimum (10s). Turn the LUX knob clockwise at the maximum (sun). 

2. 

Switch on the power; the sensor and the connected lamp have no signal at the beginning. After a warm-up time of 30 seconds, the sensor can start working. When the 

sensor receives the signal, the load (lamp etc.) switches on. As long as there is no further signal, the load should stop working within 10s±3s and the lamp would switch off. 

 

3. 

Turn the LUX knob counterclockwise to the minimum (-). If the ambient light is more than 10LUX, the sensor would not work and the lamp would also stop working. If the 

ambient light is less than 10LUX (darkness), the sensor would work. If there is no induction signal, the sensor should stop working within 10s ± 3s.

 

Note:

 When testing in daylight, please turn the LUX knob to the (SUN) position, otherwise the sensor lamp might not test! 

Solutions in case of problems   

 

 

 

 

 

 

                         

 

 

 

                 

 

The load (e.g. lights) does not work: 

1. Please check whether all cables have been connected correctly and whether the main switch (fuse box) has been switched on.

 

2. Please check that the load is correctly connected to the power cable and that it is generally fully functional.

 

3. Please check whether the sensitivity (LUX) settings may be set too low.

 

The motion detector does not sound correctly: 

1. Please check if there is an obstacle in front of the motion detector that prevents it from receiving the signals.

 

2. Please check if the ambient temperature (-20° to +40°) is too high.

 

3. Please check if the movement is within the maximum detection range (12 metres).

 

4. Please check whether the installation height corresponds to the height described in the technical data.

 

5. Please check that the motion detector has been set (rotated) so that it is aligned with the area to be detected.

 

The load does not switch off automatically:

 

1. Please check if there is a continuous signal in the detection field (moving trees etc.).

 

2. Please check if the time delay is set to the maximum position, in this case the time is set to 15 min.

Settings & troubleshooting – KELEA motion detector 990070794 / 990070795 

 

 

                                                

    

 

            

Notes / explanations & legend 

Important information                            

 

Protection class II

Installation only by qualified electrician

Disconnect the device from the mains 

power before starting any work

Disposal 

instructions 

   

Make sure to dispose packaging in 

accordance with the applicable guidelines 

of your local authority. Devices marked 

with the crossed-out waste garbage do not 

belong in the household waste! You are 

obliged to hand in these devices at one of 

the free collection points in your municipa-

lity. You can obtain more information from 

your local authority, the relevant town hall 

or a local or regional waste disposal company.

 

Keep packaging material and small parts away from 

children and animals. Danger of suffocation!

Notes on use indoors & outdoors    

 

 

Protection type IP20 & IP23: 

Use only indoors and 

dry, i.e. do not use in damp or dirty rooms and in areas 
of high humidity.

 

Protection type IP4X, IP5X & IP6X: 

Can be used 

indoors and outdoors.

Onlineshop:

www.led-lichtraum.de

Satisfied with your product?

 

Then we look forward to your product review 

in our online store, on Amazon or eBay!

SSC-LUXon GmbH – Am Krozinger Weg 4, 79189 Bad Krozingen,  
Germany – E-Mail: service@ssc-luxon.de; Phone: +49 7633 - 988 

Vers. 02/2022

Reviews: