3-2
Installing the Servo Drive
07-01-08-02-E-V0500 631 Digital Servo Drive
Mechanical Installation
W
H2
H1
H
W1
D
H3
easily re-positioned to allow
different mounting configurations
Fixing hole
centres
DIN mounting
dimensions
SIDE VIEW
PANEL MOUNTING VIEW
DIN MOUNTING VIEW
Adjustable mounting clip can be
Figure 3-1 Mechanical Dimensions for 631
631 Model Number
631 Model Number
631 Model Number
631 Model Number
H
H
H
H
H1
H1
H1
H1
H2
H2
H2
H2
H3
H3
H3
H3
W
W
W
W
W1
W1
W1
W1
D
D
D
D
Fixings
Fixings
Fixings
Fixings
631 /001 /230/ ....
Mounting holes 5.5mm
631 /002/ 230/ ....
183.0
188.0
205.0
151.0
72.0
36.0
175.0
Use M5 fixings
631 /004/ 230/ ....
(7.2)
(7.4)
(8.1)
(5.9)
(2.8)
(1.4)
(6.9)
Weight 1.5kg (3.3lb) approximately
631 /006/ 230/ ....
All dimensions are in millimetres (inches)
Note:
Additional space is required to the front of the unit for the signal mating plugs,
approximately 45mm.
Mounting the Servo Drive
The unit must be installed in a vertical position to guarantee the best air circulation for the
cooling ribs of the heat sink. Vertical installation above other drive racks or above other heat
producing devices can lead to overheating.
You must install the unit inside a suitable cubicle. The inside of this cubicle must be free from
dust, corrosive fumes, gases, and all liquids including condensation.
If the unit is being installed in a place where condensation is likely, install a suitable
anticondensation heater. The heater must be SWITCHED OFF during normal operation.